6 List Sequence Measurements
List Sequence Measurements
works when Radio
Device is MS, sweep
time value is fixed to 1
[:SENSe]:PVTime:MASK:SELect CUSTom|STANdard
[:SENSe]:PVTime:MASK:SELect?
(Note 1)
Limit Mask
Selection
[:SENSe]:PVTime:MASK:LIST:LOWer:ABSolute <ampl>,
<ampl>, <ampl>, <ampl>
[:SENSe]:PVTime:MASK:LIST:LOWer:ABSolute?
(Note 1)
Lower Mask
Absolute
Amplitude
Levels
[:SENSe]:PVTime:MASK:LIST:LOWer:POINts?
(Note 1)
Lower Mask
Points
[:SENSe]:PVTime:MASK:LIST:LOWer:RELative <ampl>,
<ampl>, <ampl>, <ampl>
[:SENSe]:PVTime:MASK:LIST:LOWer:RELative?
(Note 1)
Lower Mask
Relative
Amplitude
Levels
[:SENSe]:PVTime:MASK:LIST:LOWer:TIME <time>,
<time>, <time>, <time>
[:SENSe]:PVTime:MASK:LIST:LOWer:TIME?
(Note 1)
Lower Mask
Time Points
[:SENSe]:PVTime:MASK:LIST:UPPer:ABSolute <ampl>,
<ampl>, <ampl>, <ampl>
[:SENSe]:PVTime:MASK:LIST:UPPer:ABSolute?
(Note 1)
Upper Mask
Absolute
Amplitude
Levels
[:SENSe]:PVTime:MASK:LIST:UPPer:POINts?
(Note 1)
Upper Mask
Points
[:SENSe]:PVTime:MASK:LIST:UPPer:RELative <ampl>,
<ampl>, <ampl>, <ampl>
[:SENSe]:PVTime:MASK:LIST:UPPer:RELative?
(Note 1)
Upper Mask
Relative
Amplitude
Levels
[:SENSe]:PVTime:MASK:LIST:UPPer:TIME <time>,
<time>, <time>, <time>
[:SENSe]:PVTime:MASK:LIST:UPPer:TIME?
(Note 1)
Upper Mask
Time Points
[:SENSe]:SLOT
TS0|TS1|TS2|TS3|TS4|TS5|TS6|UPTS|DPTS
[:SENSe]:SLOT?
(Note 2)
Analysis
Timeslot
Sequencer PVT
measurement will
return “Measurement
Error” when Analysis
TimeSlot is DwPTS,
TS4, TS5 or TS6
[:SENSe]:RADio:CONFigure:HSDPa[:STATe] 0|1|OFF|ON
[:SENSe]:RADio:CONFigure:HSDPa[:STATe]?
(Note 2)
HSPA/8PSK
Enable
[:SENSe]:TDEMod:SCODe <integer>
[:SENSe]:TDEMod:SCODe?
(Note 2)
Scramble
Code
[:SENSe]:TDEMod:UPTS <integer>
[:SENSe]:TDEMod:UPTS?
(Note 2)
Uplink Pilot
316