6 List Sequence Measurements
Source
Notes
The command is to setup below parameter array of whole list sequence.
Frequency/Channel Number <
freq
>/<chan num> – specifies the frequency in Hz or the channel
number for the step. The channel number and frequency are combined as one parameter that
represents the frequency or channel number depending on the radio band setting. If the radio band is
set to NONE, this value is interpreted as a frequency value in Hz. If the radio band is set to a valid
band, this value is interpreted as a channel number. For details of the valid ranges for frequency and
channel numbers, see
and
This SCPI is used to setup/query channel number or frequency setting, according to current Radio
Band setting of that step. If Radio Band is “NONE”, then it’s frequency. If Radio Band is not “NONE”,
then it’s channel number
If input parameter number exceeds the step number defined by
Number of Steps then generate error ", and only those parametes whose index number falls in
legal step number will be updated.
Dependencies
The range is 1 to 1000 which is determined by the number of steps you have configured. For details
see
Initial S/W Revision
A.09.40
Step Configuration of Power parameter list (Remote Command Only)
This SCPI command is to configure “Power”parameter array of the whole List Sequencer at one time. The
number of array is same as step number defined in
Number of Steps. As a
step is setup, the value entered run through several levels of validation.
Remote Command
:SOURce:LIST:SETup:AMPLitude <ampl>, <ampl>, <ampl>, …
:SOURce:LIST:SETup:AMPLitude?
Example
:SOUR:LIST:SET:AMPL –50dBm,–40dBm,–30dBm
:SOUR:LIST:SET:AMPL?
Notes
The command is to setup below parameter array of whole list sequence.
Power <
ampl
> – specifies the output power for the step in dBm. For details of the valid ranges see
If input parameter number exceeds the step number defined by
Number of Steps then generate error ", and only those parametes whose index number falls in
legal step number will be updated.
Dependencies
The range is 1 to 1000 which is determined by the number of steps you have configured. For details
see
Initial S/W Revision
A.09.40
Step Configuration of Waveform parameter list (Remote Command Only)
This SCPI command is to configure “Waveform” parameter array of the whole List Sequencer at one time.
The number of array is same as step number defined in
Number of Steps.
As a step is setup, the value entered run through several levels of validation.
Remote Command
:SOURce:LIST:SETup:WAVeform <string>, <string>, <string>, …
Sequence Analyzer User's & Programmer's Reference
635