6 List Sequence Measurements
Source
Min
The range of values depends on the current frequency and selected RF output port. Please refer to
and the table RF Power Range for the valid ranges.
Max
The range of values depends on the current frequency and selected RF output port. Please refer to
and the table RF Power Range for the valid ranges.
Initial S/W Revision
A.05.00
Waveform
Allows you access to the sub-menus for selecting the waveform to be played back during the current step.
Pressing this key also changes the central display area to show the Waveform File Selection view.
Key Path
Source, List Sequencer, List Sequencer Setup
Remote Command
:SOURce:LIST:STEP[1]|2|3…1000:SETup:WAVeform <string>
:SOURce:LIST:STEP[1]|2|3…1000:SETup:WAVeform?
Example
:SOUR:LIST:STEP2:SET:WAV “CW”
:SOUR:LIST:STEP2:SET:WAV?
Notes
SCPI is supported after A.09.40
Remote Command Notes
String type, takes “Off” | “CW” | “Cont” | “waveform name”
Preset
CW
Range
Waveform | Continue Previous | CW | Off
Initial S/W Revision
A.05.00
CW
Sets the current step to output a CW tone.
Key Path
Source, List Sequencer, List Sequencer Setup, Waveform
Example
:SOUR:LIST:STEP2:SET:WAV “CW”
Notes
SCPI is supported after A.09.40
Initial S/W Revision
A.05.00
Selected Waveform
Inserts the currently selected waveform in the waveform selection view as the waveform for playback
during the current step.
Key Path
Source, List Sequencer, List Sequencer Setup, Waveform
Example
:SOUR:LIST:STEP2:SET:WAV “waveform name”
Notes
SCPI is supported after A.09.40
If the selected waveform contains header (which contains ARB play parameters), source list
Sequence Analyzer User's & Programmer's Reference