![Keysight E6650A EXF User Programming Manual Download Page 321](http://html1.mh-extra.com/html/keysight/e6650a-exf/e6650a-exf_user-programming-manual_1961647321.webp)
6 List Sequence Measurements
List Sequence Measurements
[:SENSe]:EORFSpectrum:SWITching:RPOWer?
Reference
Power
parameter_table_23.53758
52.93301
Help Map ID
35219
EDGE EVM Measurement Setup
The EDGE EVM measurement used in the GSM mode is used in the sequencer. The measurement
parameters usable within the List Sequencer measurement are listed below. For complete details of each
parameter, please see the online help associated with the measurement.
The SCPI that is used within the Sequence Analyzer mode is the same as in the GSM/EDGE mode, except
that two additional nodes are required in the Sequence Analyzer mode: one to identify the List Sequencer
measurement and one to identify the mode from which the measurement comes. For example,
[:SENSe]:EEVM is replaced with [:SENSe]:LSEQuencer:EDGE:EEVM: or
:CALCulate:LSEQuencer:EDGE:EEVM:
non_parameter_table_32.9902
9.289216
12.64706
9.918301
15.22059
Command
Description
Notes
[:SENSe]:EEVM:BSYNc:SOURce
Burst Sync
:CALCulate:EEVM:LIMit:TEST[:STATe]
Limit Test State
:CALCulate:EEVM:LIMit:TYPE
Test Condition
:CALCulate:EEVM:LIMit:BTS:NORMal:REVM
EVM Test Limit (BTS,
Normal)
:CALCulate:EEVM:LIMit:BTS:EXTReme:REVM
EVM Test Limit (BTS,
Extreme)
:CALCulate:EEVM:LIMit:MS:NORMal:REVM
EVM Test Limit (MS,
Normal)
:CALCulate:EEVM:LIMit:MS:EXTReme:REVM
EVM Test Limit (MS,
Extreme)
:CALCulate:EEVM:LIMit:BTS:NORMal:REVM:NSRate
NB 16/32 QAM EVM Test
Limit (BTS, Normal)
:CALCulate:EEVM:LIMit:BTS:EXTReme:REVM:NSRate
NB 16/32 QAM EVM Test
Limit (BTS, Extreme)
:CALCulate:EEVM:LIMit:MS:NORMal:REVM:NSRate
NB 16/32 QAM EVM Test
Limit (MS, Normal)
:CALCulate:EEVM:LIMit:MS:EXTReme:REVM:NSRate
NB 16/32 QAM EVM Test
Limit (MS, Extreme)
:CALCulate:EEVM:LIMit:BTS:NORMal:REVM:HSRate
HB 16/32 QAM / QPSK
EVM Test Limit (BTS,
Normal)
Sequence Analyzer User's & Programmer's Reference
321