6 List Sequence Measurements
Meas Setup
parameter_
table_
23.52941
52.94118
Key Path
Meas Setup, Acquisition Setup, Radio Setup
Remote
Command
-To set Radio Device individually:
[:SENSe]:LSEQuencer:ACQuire{1:512}:SETup:RADio:DEVice < BTS | MS >
[:SENSe]:LSEQuencer:ACQuire{1:512}:SETup:RADio:DEVice?
-To set Radio Device as an array:
[:SENSe]:LSEQuencer:LIST:SETup:RADio:DEVice <enum>,<enum>,<enum>,….
[:SENSe]:LSEQuencer:LIST:SETup:RADio:DEVice?
The array form of the command is used to make a different setting for each acquisition in the sequence (the
number of array values must match the number of acquisitions; otherwise a "settings conflict" error will occur).
Example
:LSEQ:ACQ2:SET:RAD:DEV MS
:LSEQ:ACQ2:SET:RAD:DEV?
:LSEQ:LIST:SET:RAD:DEV MS,MS,MS
:LSEQ:LIST:SET:RAD:DEV?
Notes
For setting this parameter using SCPI, see
"Programming Acquisitions Via SCPI" on page 376
.
This parameter and the Band parameter are used to determine which Channel Plan is to be used.
Couplings
Coupled to Channel number, Band and Radio Standard parameters
Preset
BTS (only with x9065x–1FP license)
MS (otherwise)
State Saved
Saved in instrument state.
Range
BTS | MS
Initial S/W
Revision
A.05.00
Help Map ID
35106
Channel
This parameter sets the channel for the current acquisition. If a Radio Standard other than None is selected
for the acquisition, this parameter and the Frequency parameter are coupled (changing either parameter
changes the other as well). If the Radio Standard for the acquisisition if None, this parameter is not
applicable; in that case, set Frequency instead.
parameter_
52.94118
Sequence Analyzer User's & Programmer's Reference
421