Goodrive600 series high-performance multifunction VFD
Basic operation guidelines
-66-
Function
code
Name
Description
Default
P02.00
Type of motor 1
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
P02.02
Rated frequency of AM 1 0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
P02.04
Rated voltage of AM 1
0
–1200V
Model
depended
P04.00
V/F curve setting of motor
1
0: Straight-line V/F curve
1: Multi-point V/F curve
2: Torque-down V/F curve (power of 1.3)
3: Torque-down V/F curve (power of 1.7)
4: Torque-down V/F curve (power of 2.0)
5: Customized V/F curve (V/F separation):
0
P04.01
Torque boost of motor 1
0.1%
–10.0%
0.0%: Automatic
0.0%
P04.02
Torque boost cut-off of
motor 1
0.0%
–50.0% (of the rated frequency of motor 1)
20.0%
P04.03
V/F frequency point 1 of
motor 1
0.00Hz
–P04.05
0.00Hz
P04.04
V/F voltage point 1 of
motor 1
0.0%
–110.0%
0.0%
P04.05
V/F frequency point 2 of
motor 1
P04.03
–P04.07
0.00Hz
P04.06
V/F voltage point 2 of
motor 1
0.0%
–110.0%
0.0%
P04.07
V/F frequency point 3 of
motor 1
P04.05
–P02.02 or P04.05–P02.16
0.00Hz
P04.08
V/F voltage point 3 of
motor 1
0.0%
–110.0%
0.0%
P04.09
V/F slip compensation gain
of motor 1
0.0
–200.0%
100.0%
P04.10
Low-frequency oscillation
control factor of motor 1
0
–100
10
P04.11
High-frequency oscillation
control factor of motor 1
0
–100
10
P04.12
Oscillation control
threshold of motor 1
0.00Hz
–P00.03 (Max. output frequency)
30.00Hz
P04.13
V/F curve setting of motor
2
0: Straight-line V/F curve
1: Multi-point V/F curve
2: Torque-down V/F curve (power of 1.3)
3: Torque-down V/F curve (power of 1.7)
4: Torque-down V/F curve (power of 2.0)
5: Customized V/F curve (V/F separation):
0
P04.14
Torque boost of motor 2
0.1%
–10.0%
0.0%: Automatic
0.0%
P04.15
Torque boost cut-off of
motor 2
0.0%
–50.0% (of the rated frequency of motor 2)
20.0%
P04.16
V/F frequency point 1 of
motor 2
0.00Hz
–P04.18
0.00Hz