Goodrive600 series high-performance multifunction VFD
Function parameter list
-321-
Function
code
Name
Description
Default Modify
indicates 0.25
μs.
P20.19
Pulse reference filter
width
Range: 0
–63
The filter time is P20.19*0.25
μs. The value 0 or 1
indicates 0.25
μs.
2
○
P20.20
Pulse number of pulse
reference
0
–65535
1024
◎
P20.21
Enabling SM angle
compensation
0
–1
0
○
P20.22
Frequency point of
speed measurement
mode switchover
Range: 0
–630.00Hz
Note: Valid only when P20.12=0.
1.00Hz
○
P20.23
SM angle compensation
coefficient
-200.0
–200.0%
100.0%
○
P20.24
Pole pairs in SM pole
initial angle autotuning
0
–128
2
○
P21 group
––Position control
Function
code
Name
Description
Default Modify
P21.00
Positioning mode
Ones place: Control mode selection (only for
closed-loop vector control)
0: Speed control
1: Position control
Tens place: Position command source
0: Pulse string, using PG card terminal (A2, B2)
pulse giving signal for position control
1: Digital position, using the setting of P21.17 for
position control, while the positioning mode can
be set through P21.16
2: Positioning of photoelectric switch during stop.
When a terminal receives a photoelectric switch
signal (selection terminal function 43), the VFD
starts positioning for stop, and the stop distance
can be set through P21.17.
Hundred place: Position feedback source
0: Encoder signal
1: Reserved
Thousands: Servo mode
Bit0: Position deviation mode
0: No deviation
1: With deviation
Bit1: Enable/disable servo
0: Disable (The servo can be enabled by
terminals.)
1: Enable
Bit2: Reserved
Note:
In the pulse string or spindle positioning
0x0000
○