Goodrive600 series high-performance multifunction VFD
Optional peripheral accessories
-406-
INVT provides some of the filters for you to choose.
E.7.1 Filter model description
FLT
–
P 04 045 L
–
B
①
②
③
④
⑤
⑥
Field
Description
①
FLT: VFD filter series
②
Filter type
P: Power input filter
L: Output filter
③
Voltage class
04: AC 3PH 380V (-15%)
–440V (+10%)
06: AC 3PH 520V (-15%)
–690V (+10%)
④
3-digit code indicating the rated current. For example, 015 indicates 15 A.
⑤
Filter performance
L: General
H: High-performance
⑥
Filter application environment
A: First environment (IEC61800-3), category C1 (EN 61800-3)
B: First environment (IEC61800-3), category C2 (EN 61800-3)
C: Second environment (IEC61800-3), category C3 (EN 61800-3)
E.7.2 Filter model selection
Rectifier unit model
Input filter
GD600-71-045-4-B
FLT-P04100L-B
GD600-71-160-4
FLT-P04400L-B
GD600-71-355-4
FLT-P04800L-B
Inverter unit model
Output reactor
GD600-51-1R5-4
FLT-L04006L-B
GD600-51-2R2-4
GD600-51-004-4
FLT-L04016L-B
GD600-51-5R5-4
GD600-51-7R5-4
FLT-L04032L-B
GD600-51-011-4
GD600-51-015-4
FLT-L04045L-B
GD600-51-018-4
GD600-51-022-4
FLT-L04065L-B
GD600-51-030-4
GD600-51-037-4
FLT-L04100L-B
GD600-51-045-4
GD600-51-055-4
FLT-L04150L-B
GD600-51-075-4
Note:
The input EMI meets the C2 requirements after an input filter is configured.