Goodrive600 series high-performance multifunction VFD
Basic operation guidelines
-85-
0
1
2
3
.
.
.
.
.
.
28
29
P06.14
AO1
P06.17
P06.18
P06.19
P06.20
P06.22
P06.23
P06.24
P06.25
P06.21
(Default value is 0)
Analog output curve
setting
Analog output
selection
Analog output filter
AO output relationship description:
(The min. value and max. value of the output correspond to 0.% and 100.00% of the pulse or analog default output. The
actual output voltage or pulse frequency corresponds to the actual percentage, which can be set through function
codes.)
Setting
Function
Description
0
Running frequency
0
–Max. output frequency
1
Set frequency
0
–Max. output frequency
2
Ramp reference frequency
0
–Max. output frequency
3
Running speed
0
–Synchronous speed corresponding to max. output
frequency
4
Output current (relative to the inverter
unit)
0
–Twice the inverter unit rated current
5
Output current (relative to motor)
0
–wice the motor rated current
6
Output voltage
0
–1.5 times the inverter unit rated voltage
7
Output power
0
–Twice the motor rated power
8
Set torque value (bipolar)
0
–Twice the motor rated current. A negative value
corresponds to 0.0% by default.
9
Output torque (absolute value)
0
–±(Twice the motor rated torque)
10
AI1 input
0(2)
–10V/0(4)–20mA
11
AI2 input
0V
–10V. A negative value corresponds to 0.0% by
default.
12
AI3 input
0(2)
–10V/0(4)–20mA
13
Reserved
14
Value 1 set through Modbus
communication
0
–1000
15
Value 2 set through Modbus
communication
0
–1000
16
Value 1 set through
PROFIBUS-DP/DeviceNet
communication
0
–1000
17
Value 2 set through
PROFIBUS-DP/DeviceNet
communication
0
–1000
18
Value 1 set through Ethernet
communication
0
–1000