Goodrive600 series high-performance multifunction VFD
Function parameter list
-298-
Function
code
Name
Description
Default Modify
P12.14
Magnetic saturation
coefficient 4 of iron core
of AM 2
0.0
–100.0%
40%
○
P12.15
Rated power of SM 2 0.1
–3000.0kW
Model
depended
◎
P12.16
Rated frequency of SM
2
0.01Hz
–P00.03 (Max. frequency)
50.00Hz
◎
P12.17
Number of pole pairs of
SM 2
1
–128
2
◎
P12.18
Rated voltage of SM 2 0
–1200V
Model
depended
◎
P12.19
Rated current of SM 2 0.8
–6000.0A
◎
P12.20
Stator resistance of SM
2
0.001
–65.535Ω
○
P12.21
Direct-axis inductance
of SM 2
0.01
–655.35mH
○
P12.22
Quadrature-axis
inductance of SM 2
0.01
–655.35mH
○
P12.23
Counter-emf constant of
SM 2
0
–10000V
300
○
P12.24
Initial pole position of
SM 2 (reserved)
0
–0xFFFF
0x0000
●
P12.25
Identification current of
SM 2 (reserved)
0%
–50% (of the motor rated current)
10%
●
P12.26
Overload protection
selection of motor 2
0: No protection
1: Common motor (with low-speed
compensation)
2: Frequency-variable motor (without low-speed
compensation)
2
◎
P12.27
Overload protection
coefficient of motor 2
Motor overload multiples M=Iout/(In*K)
"In" is rated motor current, "lout" is inverter unit
output current, and "K" is motor overload
protection coefficient.
A smaller value of K indicates a bigger value of
M.
When M=116%, protection is performed after
motor overload lasts for 1 hour; when M=150%,
protection is performed after motor overload
lasts for 12 minutes; when M=200%, protection
is performed after motor overload lasts for 60
seconds; and when M≥400%, protection is
performed immediately.
100.0%
○