Goodrive600 series high-performance multifunction VFD
Function parameter list
-265-
Function
code
Name
Description
Default Modify
2: Torque-down V/F curve (power of 1.3)
3: Torque-down V/F curve (power of 1.7)
4: Torque-down V/F curve (power of 2.0)
5: Customized V/F curve (V/F separation)
P04.14
Torque boost of motor 2
0.0%: Automatic
0.1%
–10.0%
0.0%
○
P04.15
Torque boost cut-off of
motor 2
0.0%
–50.0% (of the rated frequency of motor 2)
20.0%
○
P04.16
V/F frequency point 1 of
motor 2
0.00Hz
0.00Hz
○
P04.17
V/F voltage point 1 of
motor 2
0.0%
–110.0% (of the rated voltage of motor 2)
00.0%
○
P04.18
V/F frequency point 2 of
motor 2
0.00Hz
○
P04.19
V/F voltage point 2 of
motor 2
0.0%
–110.0% (of the rated voltage of motor 2)
00.0%
○
P04.20
V/F frequency point 3 of
motor 2
–P12.02 (Rated frequency of AM 2)
–P12.16 (Rated frequency of SM 2)
0.00Hz
○
P04.21
V/F voltage point 3 of
motor 2
0.0%
–110.0% (of the motor rated voltage)
00.0%
○
P04.22
V/F slip compensation
gain of motor 2
0.0
–200.0%
0.0%
○
P04.23
Low-frequency
oscillation control factor
of motor 2
0
–100
10
○
P04.24
High-frequency
oscillation control factor
of motor 2
0
–100
10
○
P04.25
Oscillation
control
threshold of motor 2
0.00Hz
–P00.03 (Max. frequency)
30.00Hz
○
P04.26
Energy-saving run
0: Disable
1: Automatic energy-saving run
In light-load state, the motor can adjust the
output voltage automatically to achieve energy
saving.
0
◎
P04.27
Voltage setting channel
0: Keypad (The output voltage is determined by
1: AI1
2: AI2
3: AI3
4: Reserved
5: Multi-step speed running (The setting is
determined by group P10.)
6: PID
7: Modbus communication
8: CANopen communication
9: Ethernet communication
0
○