background image

Sun. Water. 

Life.

BERNT LORENTZ GmbH & Co. KG 

Kroegerskoppel 7, 24558 Henstedt-Ulzburg, Germany, Tel. +49 (0) 4193 7548 - 0, Fax - 29, 

www.lorentz.de

 

Errors excepted and possible alterations without prior notice.

111001

PP4000 AC PowerPack

AC/DC converter to power PS4000 pump systems 
from a generator or utility power 
 

InStAllAtIon

WArnIng this device is to be installed, 

connected and serviced by qualified 
personnel only. Ensure all power sourc-
es are disconnected when making con-

nections to this unit. Follow all appropriate electri-
cal codes. there are no user-serviceable parts inside.

Mounting

Mount the AC PowerPack close to the pump controller, in 
a vertical position. Cover the unit from direct rainfall. You 
will find four mounting brackets in a plastic bag inside the 
enclosure. 

WArnIng PowerPack must be protect-

ed from solar heat, especially direct 
mid-day sun. Mount it in the shade. If 
there is no shady location, make a 
shade from sheet metal. Allow free air 
circulation around the cooling fins on 
the back of the enclosure. 

WArnIng Power Pack must be oFF 

while it is being wired to the solar 
pump controller, or controller damage 
may result. never connect it while it is 
“hot”.

Connections

For all connections, see the description on the sticker on the 
back of the device.

Wire Sizes

All wires must be #14 AWG (2.5 mm

2

) or larger.

grounding

Connect propper ground to the yellow-green wire of the 
AC cable.

AC Input

Connect propper ground to the yellow-green wire of the AC 
cable. Connect AC power to the phases L1, L2, L3. As there 
is always a ballanced load on the three phases, a neutral 
connection is obsolete. Be aware, that in most installation 
codes it is not allowed to use a 5-pole plug (3P + 1N + 1 
PE) for this, because the neutral is not connected. Use a 
4-pole plug instead, according to the local standards.

DC PoWEr oUt

Connect the two wires from the DC POWER OUT plug to 
the POWER IN + and – terminals in the solar pump control-
ler. Install a properly rated DC disconnect switch between 
the PP4000 and the solar pump controller if it is operated 
together with a solar generator. Install a properly rated DC 
disconnect switch between the solar generator and the 
pump controller, too. 

WArnIng – only one of the power 

sources must connected at a time.

photo may differ from actual product

APPlICAtIon

the Problem

Some solar pumps may not provide sufficient flow under all 
conditions, especially in unusually cloudy weather or when 
sufficient storage cannot be provided.

the Solution

LORENTZ AC PowerPack allows the pump to be powered by 
an AC generator or commercial utility power. The PowerPack 
will power the pump to its full capacity. With some systems, 
it will produce a greater flow rate than you will see with 
solar power.

SPECIFICAtIonS

AC input: 380 V (±20 %), 45 to 65 Hz

 

DC output: 180-286  V, 5.7 k W

 

DC output rated current: 20 A @ 230 V DC

 

overload protection: internal fuse, 10 A

 

enclosure: steel, gasket-sealed, outdoor-rated,  

 

hinged front cover with key-lock
must be protected from direct mid-day sun

 

IP42

 

ambient temperature: –5 to 45°C

 

efficiency up to 94%

 

passive cooling, no fan

 

DIMEnSIonS

332 mm × 210 mm × 201.8 mm 

 

15.7 in × 8.7 in × 8.3 in
weight: 14.5 kg/30 lbs.

 

WArrAnty 

Warranted to be free from defects in material and work-
man-ship for TWO YEARS from date of purchase.

Figure 1: Wiring

DC switch

DC switch

solar 

array

+ –

Power

 

In

PS4000 

Controller

1

1

1

2

2

phases

ground

3

3

3

4

4

4

2

DC

AC

Reviews: