Fabric OS 5.2.x administrator guide 291
Correcting device login issues
To try to pinpoint problems with device logins, use this procedure:
1.
Log in to the switch as
admin
.
2.
Enter the
switchShow
command; then, check for correct logins:
3.
Enter the
portCfgShow
command to see how the port is configured:
switch:admin>
switchshow
switchName: sw094135
switchType: 26.1
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 126
switchId: fffc7e
switchWwn: 10:00:00:05:1e:34:00:69
zoning: ON (cfg_em)
switchBeacon: OFF
Port Media Speed State
=========================
0 id N1 Online E-Port 10:00:00:60:69:11:f9:fc “2800_116”
1 id 1G Online E-Port 10:00:00:60:69:11:f9:fc “2800_116”
2 id N2 No_Light
3 id 2G No_Light
4 id N2 Online E-Port (Trunk port, master is Port 5)
5 id N2 Online E-Port 10:00:00:05:1e:34:00:8b “Dazz125”
(downstream)(Trunk master)
6 id N2 No_Light
7 id N2 No_Light
8 id N1 Online L-Port 4 public, 1 private, 1 phantom
9 id N2 No_Light
10 id N2 Online G-Port
11 id N2 Online F-Port 10:00:00:01:c9:28:c7:01
12 id N1 Online L-Port 4 public, 1 private, 1 phantom
13 -- N2 No_Module
14 id N2 Online E-Port (Trunk port, master is Port 15)
15 id N2 Online E-Port 10:00:00:60:69:90:03:17 “TERM_113”
(downstream)(Trunk master)
switch:admin>
portcfgshow
Ports of Slot 8 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
-----------------+--+--+--+--+----+--+--+--+----+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN
Trunk Port ON ON ON ON ON ON ON ON .. ON ON ON ON ON ON ..
Long Distance .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
VC Link Init .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked L_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ISL R_RDY Mode .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
RSCN Suppressed .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
Persistent DisableON ON ON ON ON ON ON ON .. ON ON ON ON ON ON ON
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
EX Port .. .. .. .. .. .. .. .. ON .. .. .. .. .. .. ..
where AN:AutoNegotiate, ..:OFF, ??:INVALID.
LM:L0.5
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......