Fabric OS 5.2.x administrator guide 237
6.
Log in to the switch and issue the
nsAllShow
or the
nsCamShow
command.
All of the devices from both LSANs should appear in the output. If the devices do not appear in the
output, issue the
cfgShow
command to verify your zone configuration. Use the
cfgactvshow
command to display the zone configuration currently in effect. The following example illustrates the use
of
cfgactvshow
.
7.
Log into the FC router and run the
lsanZoneShow
command to verify FIDs and devices to be shared
among LSANs.
edgeswitch:admin_06>
nsallshow
{
010e00 020000 03f001 04f002
4 Nx_Ports in the Fabric }
edgeswitch:admin_06>
nscamshow
nscam show for remote switches:
Switch entry for 1
state rev owner
known v520 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 010e00; 3;10:00:00:00:00:01:00:00;10:00:00:00:00:00:01:00;
Fabric Port Name: 20:0e:00:60:69:e2:18:b6
Permanent Port Name: 10:00:00:00:00:01:00:00
Port Index: 14
Share Area: No
Device Shared in Other AD: No
Switch entry for 3
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 03f001; 2,3;10:00:00:00:c9:44:54:04;20:00:00:00:c9:44:54:04;
FC4s: FCP
NodeSymb: [36] "Emulex LP9002 FV3.92A2 DV5-5.10A10 "
Fabric Port Name: 50:00:51:e3:70:9a:3d:e8
Permanent Port Name: 10:00:00:00:c9:44:54:04
Port Index: na
Share Area: No
Device Shared in Other AD: No
Switch entry for 4
state rev owner
known v410 0xfffc02
Device list: count 1
Type Pid COS PortName NodeName
N 04f002; 3;10:00:00:00:00:03:00:00;10:00:00:00:00:00:03:00;
Fabric Port Name: 50:06:06:91:23:45:6a:13
Permanent Port Name: 10:00:00:00:00:03:00:00
Port Index: na
Share Area: No
Device Shared in Other AD: No
switch:admin> cfgactvshow
Effective configuration:
cfg:
test
zone:
lsan_san
10:00:00:00:00:03:00:00
10:00:00:00:00:01:00:00
zone:
lsan_test
50:06:01:60:38:e0:0b:a4
10:00:00:00:c9:44:54:04
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......