Fabric OS 5.2.x administrator guide 159
9.
Optionally, after the failover, connect to the switch, log in again as
admin
. Using a separate telnet
session, enter the
firmwareDownloadStatus
command to monitor the firmware download status.
switch:admin>
firmwaredownloadstatus
[1]: Fri Sep 22 09:45:15 2006
Slot 5 (CP0, active): Firmware is being downloaded to standby CP. This step may
take up to 30 minutes.
[2]: Fri Sep 22 09:51:21 2006
Slot 5 (CP0, active): Firmware has been downloaded successfully to Standby CP.
[3]: Fri Sep 22 09:51:28 2006
Slot 5 (CP0, active): Standby CP is going to reboot with new firmware.
[4]: Fri Sep 22 09:53:00 2006
Slot 5 (CP0, active): Standby CP booted successfully with new firmware.
[5]: Fri Sep 22 09:53:11 2006
Slot 10 (FC4-16IP): Firmware is being downloaded to the blade. This step may take
up to 10 minutes.
[6]: Fri Sep 22 09:53:54 2006
Slot 6 (CP1, active): Forced failover succeeded. New Active CP is running new
firmware
[7]: Fri Sep 22 09:54:01 2006
Slot 6 (CP1, active): Firmware is being download to standby CP. This step may
take up to 30 minutes.
[8]: Fri Sep 22 09:54:59 2006
Slot 10 (FC4-16IP): Firmware has been downloaded successfully. Blade is rebooting
with the new firmware.
[9]: Fri Sep 22 09:55:36 2006
Slot 10 (FC4-16IP): Firmware commit has started on the blade. This may take up to
10 minutes.
[10]: Fri Sep 22 09:56:19 2006
Slot 10 (FC4-16IP): The commit operation has completed successfully.
[11]: Fri Sep 22 10:00:30 2006
Slot 6 (CP1, active): Firmware has been downloaded successfully on Standby CP.
[12]: Fri Sep 22 10:00:38 2006
Slot 6 (CP1, active): Standby CP reboots.
[13]: Fri Sep 22 10:02:16 2006
Slot 6 (CP1, active): Standby CP booted successfully with new firmware.
[14]: Fri Sep 22 10:02:20 2006
Slot 6 (CP1, active): Firmware commit operation has started on both active and
standby CPs.
[15]: Fri Sep 22 10:06:08 2006
Slot 6 (CP1, active): Firmware commit operation has completed successfully on
both CPs.
[16]: Fri Sep 22 10:06:08 2006
Slot 6 (CP1, active): Firmwaredownload command has completed successfully. Use
firmwareshow to verify the firmware versio
ns.
switch:admin>
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......