Fabric OS 5.2.x administrator guide 313
Displaying and clearing the CRC error count
You can use the
perfShowAlpaCrc
command to display the CRC error count for all AL_PA devices or for
a single AL_PA on a specific active L_Port.
Example: Displaying the CRC error count for all AL_PA devices on a port
Example: Displaying the CRC error count for a single AL_PA device on a port
Example: Clearing the CRC error count
In v3.1.0, v4.1.0, and later versions, you can use the
portStatsClear
command clears AL_PA- based
CRC error counters for all the ports in the same group.
Monitoring end-to-end performance
End-to-end performance monitoring counts the number of words and CRC errors in Fibre Channel frames
for a specified Source ID (SID) and Destination ID (DID) pair. An end-to-end performance monitor includes
these counts:
•
RX_COUNT (words in frames received at the port)
•
TX_COUNT (words in frames transmitted from the port)
•
CRC_COUNT (frames with CRC errors received at or transmitted from the port)
To enable end-to-end performance monitoring, you must configure an end-to-end monitor on a port,
specifying the SID-DID pair (in hexadecimal). The monitor counts only those frames with matching SID and
DID.
Each SID or DID has three fields, listed in the following order:
•
Domain ID (DD)
•
Area ID (AA)
•
AL_PA (PP)
For example, the SID 0x118a0f denotes DD 0x11, AA 0x8a, and AL_PA 0x0f.
You can monitor end-to-end performance using the
perfMonitorShow
command, as described in
”
Displaying monitor counters
” on page 321. You can clear end-to-end counters using the
perfMonitorClear
command, as described in ”
Clearing monitor counters
” on page 323.
NOTE:
For end-to-end monitors, CRC counters are not displayed on the 4/16 SAN Switch and 4/8 SAN
Switch, SAN Switch 4/32, 4/64 SAN Switch, 400 MP Router and the 4/256 SAN Director.
switch:admin>
perfshowalpacrc 1/1
AL_PA CRC
count
--------------------
0xd9 0
switch:admin>
perfshowalpacrc 1/1, 0xd9
The CRC count at ALPA 0xd9 on port 1 is 0x000000000.
switch:admin> perfclearalpacrc
1/1, 0xd9
CRC error count at AL_PA 0xd9 on port 1 is cleared.
switch:admin> perfclearalpacrc
1/1
No AL_PA value is specified. This will clear all AL_PA CRC
counts on port 1. Do you want to continue? (yes, y, no, n): [no]
y
Please wait ...
All alpa CRC counts are cleared on port 1.
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......