232 Using the FC-FC routing service
For information about edge fabric setup on E_ports and interswitch linking, see ”
Administering ISL
Trunking
” on page 333. For information on EX_Port Frame trunking setup on the FCR switch, see ”
Using
EX_Port Frame trunking
” on page 223.
11.
Capture a SAN profile of the McDATA and HP SANs, identifying the number of devices in each SAN.
By projecting the total number of devices and switches expected in each fabric when the LSANs are
active, you can quickly determine the status of the SAN by issuing the commands
nsAllShow
and
fabricShow
on the HP fabric.
The
nsAllShow
displays the global name server information and
fabricShow
displays the fabric
membership information. The following examples illustrate the use of these commands.
You can use SAN Pilot or EFCM to gather similar information for the McDATA fabric.
Figure 12
EFCM SAN status
When you have configured the 400 MP Router and B-Series MP Router (FR4-18i) blade to connect to a HP
fabric, you must create LSAN and zones for the SAN. Once you have set up LSAN zoning, you can issue
the
cfgShow
command to verify that the zoning is correct.
NOTE:
The procedures related to McDATA that are described in this section were current when the
document was written, but may have changed since then. For the most up-to-date information, refer to the
McDATA documentation about zone configuration on McDATA fabrics
.
Configuring M-Series or McDATA for interconnection
To ensure connectivity with the HP fabric, you must prepare the M-Series or McDATA fabric for use with the
400 MP Router and B-Series MP Router (FR4-18i) blade.
NOTE:
The procedures related to McDATA that are described in this section were current when the
document was written, but may have changed since then. For the most up-to-date information, refer to the
McDATA documentation about zone configuration on McDATA fabrics
.
wta_switch:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
-------------------------------------------------------------------------
1: fffc01 10:00:00:60:69:e4:00:36 10.33.13.91 220.220.220.91
"wtQA_saturn91"
218: fffcda 10:00:00:60:69:90:02:b3 10.33.13.218 10.10.10.11
>"SW3900_WT218"
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......