362 Administering Advanced Zoning
To delete a zone object
1.
Connect to the switch and log in as
admin
.
2.
Enter the
cfgShow
command to view the zone configuration objects you want to delete.
3.
Enter the
zoneObjectExpunge
command to delete the zone object. Note that zone configuration
names are case sensitive; blank spaces are ignored
4.
Enter the
cfgShow
command to verify the deleted zone object is no longer present.
5.
If you want the change preserved when the switch reboots, save it to nonvolatile (also known as “flash”)
memory by entering the
cfgSave
command.
6.
For the change to become effective, enable the appropriate zone configuration using the
cfgEnable
command.
To rename a zone object
1.
Connect to the switch and log in as
admin
.
2.
Enter the
cfgShow
command to view the zone configuration objects you want to rename.
3.
Enter the
zoneObjectRename
command to rename zone configuration objects. Note that zone
configuration names are case sensitive; blank spaces are ignored
switch:admin>
cfgShow
Defined configuration:
cfg: USA_cfg Red_zone; White_zone; Blue_zone
zone: Blue_zone
1,1; array1; 1,2; array2
zone: Red_zone
1,0; loop1
zone: White_zone
1,3; 1,4
alias: array1 21:00:00:20:37:0c:76:8c; 21:00:00:20:37:0c:71:02
alias: array2 21:00:00:20:37:0c:76:22; 21:00:00:20:37:0c:76:28
alias: loop1 21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df
Effective configuration:
cfg: USA_cfg
zone: Blue_zone
1,1
21:00:00:20:37:0c:76:8c
21:00:00:20:37:0c:71:02
1,2
21:00:00:20:37:0c:76:22
21:00:00:20:37:0c:76:28
zone: Red_zone
1,0
21:00:00:20:37:0c:76:85
21:00:00:20:37:0c:71:df
switch:admin>
zoneObjectExpunge "White_zone"
switch:admin>
cfgShow
Defined configuration:
cfg: USA_cfg Red_zone; White_zone; Blue_zone
zone: Blue_zone
1,1; array1; 1,2; array2
zone: Red_zone
1,0; loop1
zone: White_zone
1,3; 1,4
alias: array1 21:00:00:20:37:0c:76:8c; 21:00:00:20:37:0c:71:02
alias: array2 21:00:00:20:37:0c:76:22; 21:00:00:20:37:0c:76:28
alias: loop1 21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df
switch:admin>
zoneObjectRename "White_zone", “Red_zone”
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......