Fabric OS 5.2.x administrator guide 293
5.
Enter the
portFlagsShow
command; then, check to see how a port has logged in and where a login
failed (if a failure occurred):
switch:admin>
portflagsshow
Slot Port SNMP Physical Flags
------------------------------------
7 0 Offline No_Module PRESENT U_PORT LED
7 1 Offline No_Module PRESENT U_PORT LED
7 2 Offline No_Module PRESENT U_PORT LED
7 3 Offline No_Module PRESENT U_PORT LED
7 4 Offline No_Module PRESENT U_PORT LED
7 5 Offline No_Module PRESENT U_PORT LED
7 6 Offline No_Module PRESENT U_PORT LED
7 7 Offline No_Module PRESENT U_PORT LED
7 8 Offline No_Module PRESENT U_PORT LED
7 9 Offline No_Module PRESENT U_PORT LED
7 10 Offline No_Module PRESENT U_PORT LED
7 11 Offline No_Module PRESENT U_PORT LED
7 12 Offline No_Module PRESENT U_PORT LED
7 13 Offline No_Module PRESENT U_PORT LED
7 14 Offline No_Module PRESENT U_PORT LED
7 15 Offline No_Module PRESENT U_PORT LED
7 16 Offline No_Module PRESENT U_PORT LED
7 17 Offline No_Module PRESENT U_PORT LED
7 18 Offline No_Module PRESENT U_PORT LED
7 19 Offline No_Module PRESENT U_PORT LED
7 20 Offline No_Module PRESENT U_PORT LED
7 21 Offline No_Module PRESENT U_PORT LED
7 22 Offline No_Module PRESENT U_PORT LED
7 23 Offline No_Module PRESENT U_PORT LED
7 24 Offline No_Module PRESENT U_PORT LED
7 25 Offline No_Module PRESENT U_PORT LED
7 26 Offline No_Module PRESENT U_PORT LED
7 27 Offline No_Module PRESENT U_PORT DISABLED LED
7 28 Offline No_Module PRESENT U_PORT LED
7 29 Offline No_Module PRESENT U_PORT LED
7 30 Offline No_Module PRESENT U_PORT LED
7 31 Offline No_Module PRESENT U_PORT LED
8 0 Offline No_Module PRESENT U_PORT DISABLED LED
8 1 Offline No_Module PRESENT U_PORT DISABLED LED
8 2 Offline No_Module PRESENT U_PORT DISABLED LED
8 3 Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN LED
8 4 Offline No_Module PRESENT U_PORT DISABLED LED
8 5 Offline No_Module PRESENT U_PORT DISABLED LED
8 6 Offline No_Module PRESENT U_PORT DISABLED LED
8 7 Offline No_Module PRESENT U_PORT DISABLED LED
8 8 Offline No_Module PRESENT U_PORT DISABLED LED
8 9 Offline No_Module PRESENT U_PORT DISABLED LED
8 10 Offline No_Module PRESENT U_PORT DISABLED LED
8 11 Online In_Sync PRESENT ACTIVE E_PORT G_PORT U_PORT LE_PORT EX_PORT
LOGICAL_ONLINE LOGIN LED
8 12 Offline No_Module PRESENT U_PORT DISABLED LED
8 13 Offline No_Module PRESENT U_PORT DISABLED LED
8 14 Offline No_Module PRESENT U_PORT DISABLED LED
8 15 Online In_Sync PRESENT ACTIVE F_PORT G_PORT U_PORT LOGICAL_ONLINE
LOGIN NOELP ACCEPT
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......