244 Administering FICON fabrics
•
Some 1-Gbit/sec storage devices cannot auto-negotiate speed with the 4/256 SAN Director or SAN
Switch 4/32 ports. For these types of devices, configure ports that are connected to 1-Gbit/sec storage
devices for fixed 1-Gbit/sec speed.
Preparing a switch
To verify and prepare a switch for use in a FICON environment, complete the following steps:
1.
Connect to the switch and log in as admin.
2.
If not in a cascaded environment, proceed to
step 3
.
If in a FICON cascaded environment, enter the following commands:
•
licenseShow
to verify that required licenses (Secure Fabric OS and Zoning) are activated
•
secModeShow
to determine if Secure Fabric OS is enabled; if it is disabled, enable it
•
secPolicyShow
to verify that the SCC_POLICY is active
•
pkiShow
to determine the existence of PKI objects, such as switch private key, private key
passphrase, CSR, root certificate, and switch certificate. If none of these objects exists, refer to the
Secure Fabric OS Administrator’s Guide
for information about creating the PKI objects and
obtaining the digital certificate file.
3.
Enter the
switchShow
command to verify that the switch and devices are online.
4.
Change the routing policy on the switch from the default exchange-based policy to the required
port-based policy for those switches with FICON devices directly attached. For the SAN Switch 4/32,
refer to the
Fabric OS Command Reference Manual
for details about the
aptPolicy
command. For
the 4/256 SAN Director, refer to the
Web Tools Administrator’s Guide
.
5.
Enter the
ficonshow
rnid
command to verify that the FICON
devices are registered with the switch.
6.
Enter the
ficonshow
lirr
command to verify that the FICON
host channels are registered to listen
for link incidents.
7.
Optionally, refer to ”
Using FICON CUP
” on page 248 for details about using FICON CUP.
Configuring a single switch
Single-switch configuration does not require IDID or fabric binding, provided that connected channels are
configured for single-byte addressing. However, you should configure IDID to ensure that domain IDs are
maintained.
Configuring a high-integrity fabric
To configure a high-integrity fabric (cascaded configuration):
1.
Disable each switch in the fabric.
2.
For each switch:
a.
Enable the IDID flag.
b.
Set the domain ID.
c.
Install security certificates and keys.
3.
Enable the switches; this builds the fabric.
4.
Set up security on the primary FCS switch.
Use the
secModeEnable
command. The security policies are distributed to each switch in the fabric.
(For details on the Quickmode procedure, refer to the
Secure Fabric OS Administrator’s Guide
.
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......