366 Administering Advanced Zoning
Table 88
Considerations for Zoning architecture
Item
Description
Type of Zoning: hard or
soft (session-based)
If security is a priority, hard Zoning is recommended.
Use of aliases
The use of aliases is optional with Zoning. Using aliases
requires structure when defining zones. Aliases will aid
administrators of zoned fabric in understanding the structure
and context.
Security requirements
Evaluate the security requirements of the fabric. If additional
security is required, add Secure Fabric OS into the fabric.
Interoperability Fabric
If the fabric includes a third-party switch product, only WWN
Zoning is supported. Other types of Zoning, including
QuickLoop, are not supported.
QLFA zones
Evaluate if the fabric will have QuickLoop Fabric Assist (QLFA)
or QuickLoop (QL) in it, and consider the following items
before creating and setting up QLFA zones:
QuickLoop Zoning—QuickLoop/QuickLoop zones cannot run
on Fabric OS v4.1.0 or later. However, Fabric OS can manage
(create, remove, update) QL zones.
QuickLoop Fabric Assist—A switch running Fabric OS v4.1.0
or later cannot have a Fabric Assist host directly connected to
it. However, such a switch can be part of a Fabric Assist zone
if a Fabric Assist host is connected to a compatible switch in
the fabric.
Testing
Testing a (new) zone configuration. Before implementing a
zone, the user should run the Zone Analyzer from Web Tools
to isolate any possible problems. This is especially useful as
fabrics increase in size.
Effect of changes in a
production fabric
Zone changes in a production fabric can result in a disruption
of I/O under conditions where an RSCN is issued as a result
of a zone change and the HBA is unable to process the RSCN
fast enough. Though RSCNs are a normal part of a
functioning SAN, the pause in I/O might not be acceptable.
For these reasons, it is recommended to perform zone changes
only when the resulting behavior is predictable and
acceptable. Changing HBA drivers can rectify the situation.
Confirming operation
After changing or enabling a zone configuration, the user
should confirm that the nodes and storage are able to identify
and access one another. Depending on the platform, the user
might need to reboot one or more nodes in the fabric with the
new changes.
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......