Fabric OS 5.2.x administrator guide
49
How to display the status of the track changes feature
1.
Connect to the switch and log in as
admin
.
2.
Enter the
trackChangesShow
command.
The status of the track changes feature is displayed as either on or off. The display includes whether the
track changes feature is configured to send SNMP traps:
How to view the switch status policy threshold values
1.
Connect to the switch and log in as admin.
2.
Enter the
switchStatusPolicyShow
command at the command line.
Whenever there is a switch change, an error message is logged and an SNMP connUnitStatusChange
trap is sent.
HP StorageWorks 4/16 SAN Switch and 4/8 SAN Switch, SAN Switch 2/8V, SAN
Switch 2/16V, SAN Switch 2/32, SAN Switch 4/32, 4/64 SAN Switch, and 400 MP
Router
:
The output is similar to the following:
HP StorageWorks SAN Director 2/128 and 4/256 SAN Director
:
The output is similar to the following:
The policy parameter determines the number of failed or inoperable units for each contributor that will
trigger a status change in the switch.
Each parameter can be adjusted so that a specific threshold must be reached before that parameter
changes the overall status of a switch to MARGINAL or DOWN. For example, if the FaultyPorts DOWN
switch:admin>
trackchangesshow
Track changes status: ON
Track changes generate SNMP-TRAP: NO
switch:admin>
switch:admin>
switchstatuspolicyshow
The current overall switch status policy parameters:
Down Marginal
----------------------------------
PowerSupplies 2 1
Temperatures 2 1
Fans 2 1
Flash 0 1
MarginalPorts 5 2
FaultyPorts 2 1
MissingSFPs 2 1
switch:admin>
switch:admin>
switchstatuspolicyshow
The current overall switch status policy parameters:
Down Marginal
----------------------------------
PowerSupplies 3 0
Temperatures 2 1
Fans 2 1
WWN 0 1
CP 0 1
Blade 0 1
Flash 0 1
MarginalPorts 2 1
FaultyPorts 2 1
MissingSFPs 0 0
switch:admin>
Summary of Contents for AE370A - Brocade 4Gb SAN Switch 4/12
Page 18: ...18 ...
Page 82: ...82 Managing user accounts ...
Page 102: ...102 Configuring standard security features ...
Page 126: ...126 Maintaining configurations ...
Page 198: ...198 Routing traffic ...
Page 238: ...238 Using the FC FC routing service ...
Page 260: ...260 Administering FICON fabrics ...
Page 280: ...280 Working with diagnostic features ...
Page 332: ...332 Administering Extended Fabrics ...
Page 414: ...398 Configuring the PID format ...
Page 420: ...404 Configuring interoperability mode ...
Page 426: ...410 Understanding legacy password behaviour ...
Page 442: ...426 ...
Page 444: ......
Page 447: ......