background image

MORE THAN METERING

Take care of your planet...

take care of you

clic

monitor.com

USER

MANUAL

Summary of Contents for CCM WIFI

Page 1: ...MORE THAN METERING Take care of your planet take care of you clicmonitor com USER MANUAL ...

Page 2: ... standards 3 10 General safety requirements 4 Device description 4 1 Identification 5 Installation 5 1 Step 1 Safety 5 2 Step 2 Connection to the principal CcM 5 3 Step 3 Power supply and turning on 6 Configuration 6 1 Access Point Mode 6 1 1 Connection types 6 2 Client Mode 6 2 1 Settings 6 2 2 Data 6 2 3 Restore 6 3 Memory 6 4 Firmware update 7 clicMONITOR App 7 1 User management 7 2 CcMs to be ...

Page 3: ...3 CcM WiFi Manual 2021 ...

Page 4: ...ests and sends the metering data to the default server clicMONITOR as we will see further below Cloud mode There is a third option through which the user defines the server to which the CcM WiFi module will send the data via FTP in CSV format FTP mode The only other way to establish a direct communi cation with the CcM product range devices without using the CcM WiFi adaptor would be via a cable c...

Page 5: ...ned to provide WiFi connection to a principal CcM device CcM2 CcM3 and CcM4 which will measure voltage current power energy and harmonics distortion in single or three pha se electrical installations connected directly to the load side of the thermal magnetic switch or resi dual current circuit breaker for use in both indus trial and domestic installations The CcM WiFi devices should only be used ...

Page 6: ...doors to be protected from corrosion and humidity 3 7 ALTERATIONS It is strictly prohibited to carry out any kind of alterations or modifications to the system 3 8 CLEANING AND MAINTENANCE Cleaning and maintenance works should only be carried out when the devices are disconnected from the grid Before taking any action make sure that the system has been correctly disconnected preventing the current...

Page 7: ...ing out the works Confirm that dangerous areas are clearly marked 3 10 GENERAL SAFETY REQUIRE MENTS Operator The person in charge of handling the electrical device is responsible for the safety of persons and property Disconnection Before starting any work disconnect the circuit breaker and check the absence of voltage in every cable that supplies voltage to the working site Prevention from inadve...

Page 8: ...r com This connector will only be used if the device hos Due to electrical hazard during insta llation it will be necessary to ensure that the installation zone meets the necessary safety conditions In order to install CcM WiFi follow these steps 5 INSTALLATION Figure 4 Identification QR code Figure 3 Graphic depiction of the bot tom part of CcM WiFi ting the CcM WiFi has been connected to other C...

Page 9: ...ally the CcM WiFi will proceed to syn chronize with the principal hosting CcM and will flash twice Since this double flash both the LED and the button of the CcM WiFi will start mirroring those on the principal CcM device which hosts it and supplies it with power At the end of this document there is an annex with examples of the possible connections in Cloud and Gateway modes between principal CcM...

Page 10: ...ork generated by the CcM WiFi device CCM_XX XX and access the generated or embedded web of the CcM WiFi de vice Once connected to the WiFi network of the CcM you should open your web browser and write http 192 168 4 1 in the address bar Figure 7 Connection to WiFi Access Point Once you write the address http 192 168 4 1 you will get to the configuration page CCM Config Web Figure 8 of the web embe...

Page 11: ...signed names shouldn t contain spaces or exceed 20 characters in length Next in the Set meter current flow mode section the user shall configure the device according to the direction of the current unidirectional or bidirectio nal mode see the manual of the principal CcM devi ce in question available at clicmonitor com Finally in the Set communication mode selection part you should select one of t...

Page 12: ...e configuration of CcM WiFi you should keep the button pressed for over 10 seconds Once you have done this the device will return to the Access Point mode and it should restart the configuration section 6 1 Once you finalize the Connection Type configura tion you should press the Send button to validate the device configuration In case the device does not obtain a valid IP address either because t...

Page 13: ... 13 It is also possi ble to create a password to lock the configuration of the CcM Access password so that it cannot be modified by anyone without the user permission Figure 12 Detail of FTP mode selection device may request and receive data from all the CcM devices connected to that bus using a WiFi in terface generated by the CcM WiFi and using the Modbus RTU over TCP protocol In this type of co...

Page 14: ...onfiguration is successful the CcM WiFi will change to Client mode described in section 6 2 In order to have a successful communi cation between the principal CcM and the CcM WiFi connected to it the prin cipal CcM must have assigned to it the default Modbus address i e 1 6 2 CLIENT MODE Once the CcM WiFi device is configured it will be connected to the local WiFi network selected du ring the Acce...

Page 15: ...b Server fields will become imple mented Device with iOs operating system Open a web browser and enter the device name By default http ChangeName local Device with Android operating system RECOMMENDED OPTION Install the clicMONITOR application sec tion 7 When you finalize the access to the device the embedded web page CcM Web Server will appear in your browser Figure 15 At this stage depending on ...

Page 16: ...ameters related to the metering realized by the principal CcM device in the phases L1 L2 and L3 In each case Act Power Active RMS Energy Voltage RMS Voltage Current RMS Current PF Power Factor In table CCM1 you may view the following para meters of up to four CcM1 C secondary devices con nected to the secondary bus of the principal CcM device The order of the devices in the table is given by the a...

Page 17: ...e logged in the session may be closed on the Restore page Figure 19 Figura 19 CcM Web Server Restore Disconnect 6 3 MEMORY If the device loses its connection to the Internet in Cloud of FTP mode it starts storing the data collec ted by the principal device to be uploaded as soon as the Internet connection is recovered The CcM WiFi has enough memory to store data for several days taking into accoun...

Page 18: ...MONITOR APP If you decide to configure the CcM WiFi using the Android application you should download it from the Google Play Store by searching clicMONITOR or using the following link https play google com store apps details id com energyccm app Once the application is downloaded and installed run it At startup the app will check the following Figure 22 Registered users CcMs to be configured Conf...

Page 19: ...ers of the EnergyCcM web portal Register a user in the application which alre ady exists and which you created before using the EnergyCcM web portal The user will enter its credentials and and will be able to check the configured and linked Figure 24 Figura 24 App clicMONITOR Gestión de usuarios EnergyCcM 7 2 CCMS TO BE CONFIGURED At the CcM to be configured section at list of the nearby CcM WiFi ...

Page 20: ... de vice will be connected 2 Name the device hostname 3 Configure the current direction see manual of the principal CcM device 4 Configure the communication mode Cloud FTP or Gateway section 6 1 1 5 Set device time zone 6 Associate user and group 7 Detail auxiliary information notes lo cation and photo 8 Set configuration password optional Figure 26 App clicMONITOR CcMs to be configured Configurat...

Page 21: ...WiFi to which the Android device is connected in order to search for CcMs configured and connected to the same network Selecting a CcM already con figured the details of this device are shown Figure 27 Consumption in real time if the Android devi ce is connected to the same WiFi network as the CcM Consumption study Cloud mode based on the data uploaded to the EnergyCcM server Configuration of the ...

Page 22: ...paired with a CcM WiFi peripheral Thus the EnergyCcM platform enables to unify various types of CcM device installations wireless or connected with a communication cable using WiFi or general master data hub such as a PLC or a PC in a single web portal accessible using any device with Internet connection PC smar tphone tablet etc EnergyCcM does not only enable to link the CcM devices but also to c...

Page 23: ...23 CcM WiFi Manual 2021 9 ANNEX EXAMPLES OF CLOUD FTP AND GATEWAY MODE CONNECTIONS ...

Page 24: ...Calle Elena Soriano 7 CP 29006 Málaga Spain Tlf 34 952 02 05 80 info clicmonitor com clicmonitor com ...