8
CcM WiFi Manual 2021
As depicted in the previous figures, the device con
-
sists of:
•
LEDs:
These are two status LEDs to indicate
the operating mode of the principal CcM devi-
ce, which hosts and connects to the CcM WiFi.
Once the CcM WiFi is connected, the LED will
flash once to indicate that it has turned on;
once it becomes synchronized with the prin-
cipal CcM, which hosts it, it will behave in the
same way as the LED of the principal CcM.
•
PUSH BUTTON:
A push button to interact
with the device. Once it is synchronized with
the CcM, it will work in the same way as the
button of the principal CcM device. Among
other functions, the button activates the Reset
mode to delete the WiFi configuration, and
the synchronisation mode to connect other
devices to the slave bus RS-485 (see manual
of the CcM device in question available at
clicmonitor.com
).
•
PRINCIPAL LOWER BUS CONNECTOR:
Con-
nector or connection interface with the princi-
pal CcM device.
•
SECONDARY LOWER BUS CONNECTOR:
Con-
nector or connection interface with the princi-
pal CcM device.
•
PRINCIPAL UPPER BUS CONNECTOR (black)
:
Extension of the connector of the principal bus
of the CcM (see manual of the CcM device in
question available at
clicmonitor.com
). This
connector will only be used if the device hos-
Due to electrical hazard during insta
-
llation, it will be necessary to ensure
that the installation zone meets the
necessary safety conditions.
In order to install CcM WiFi, follow these steps:
5. INSTALLATION
Figure 4 Identification QR code
Figure 3 Graphic depiction of the bot-
tom part of CcM WiFi
ting the CcM WiFi has been connected to other
CcM devices by cable connection using a prin-
cipal bus RS-485.
•
SECONDARY UPPER BUS CONNECTOR (red)
:
Extension of the connector of the secondary
bus of the CcM (see manual of the CcM devi-
ce in question available at
clicmonitor.com
).
This connector will only be used if the device
hosting the CcM WiFi has been connected to
other CcM devices by cable connection using a
secondary bus RS-485.
4.1 IDENTIFICATION
In the enclosure of the equipment, the user will find
an identification sticker with a QR code like the one
shown in Figure 4, in which the serial number and
MAC address of the device are coded. These serial
number and MAC are unique and are also written
next to the QR code.
5.1 STEP 1: SAFETY
Ensure that the principal CcM device
is correctly installed and connected
to a thermal-magnetic switch or resi-
dual-current circuit breaker and that
its power supply has been disconnec
-
ted so that there is no current flowing
through the CcM device (see the co
-
rresponding manual of CcM4, CcM3 or
CcM2)