Enhanced Time Processing Unit (eTPU2)
Freescale Semiconductor
29-21
PXR40 Microcontroller Reference Manual, Rev. 1
0 = Signature mismatch not detected.
This bit is cleared when Global Exception is cleared by writing 1 to GEC.
SCMMISEN — SCM MISC Enable
The SCMMISEN bit is used for enabling/disabling the operation of the MISC logic. SCMMISEN is
readable and writable at any time. The MISC logic will only operate when this bit is set to 1. When the
bit is reset the MISC address counter is set to the initial SCM address. When enabled, the MISC will
continuously cycle through the SCM addresses, reading each and calculating a CRC. In order to save
power, the MISC can be disabled by clearing the SCMMISEN bit. See
Multiple Input Signature Calculator,
for more details.
1 = MISC operation enabled.
0 = MISC operation disabled. The MISC logic is reset to its initial state.
SCMMISEN resets automatically when MISC logic detects an error, i.e., when SCMMISF transitions
from 0 to 1, disabling the MISC operation.
VIS — SCM Visibility Bit
VIS bit turns SCM visible to the IP-Bus and resets MISC state (but SCMMISEN keeps its value).
1 = SCM is visible to the slave bus. MISC state is reset.
0 = SCM is not visible to the slave bus. Accessing SCM address space issues a bus error, writes are
protected and reads are meaningless.
This bit is write protected when any of the Engines is not halted or stopped
1
. When VIS=1, the ETPUECR
MDIS bits are write protected. The value written to SCM is unspecified if other transfer sizes are used.
GTBE - Global Time Base Enable
GTBE enables time bases in both Engines, allowing them to be started synchronously.
1 = time bases in both Engines are enabled to run.
0 = time bases in both Engines are disabled to run.
NOTE
Global Time Base Enable action may also depend on other blocks, as
explained in
Section 29.3.5.4, GTBE - Global Time Base Enable
NOTE
When GTBE is turned off with Angle Mode enabled, the EAC must be
reinitialized before GTBE is turned on again. The EAC reinitialization
procedure is described in the
eTPU Reference Manual
.
1.
Engine is stopped in Module Disable or Stop Modes.
Summary of Contents for PXR4030
Page 1: ...PXR40 Microcontroller Reference Manual Devices Supported PXR4030 PXR4040 PXR40RM Rev 1 06 2011...
Page 30: ...PXR40 Microcontroller Reference Manual Rev 1 Freescale Semiconductor xxx...
Page 40: ...PXR40 Microcontroller Reference Manual Rev 1 xl Freescale Semiconductor...
Page 66: ...Memory Map PXR40 Microcontroller Reference Manual Rev 1 2 4 Freescale Semiconductor...
Page 120: ...Signal Descriptions 3 54 Freescale Semiconductor PXR40 Microcontroller Reference Manual Rev 1...
Page 860: ...FlexCAN Module 24 50 Freescale Semiconductor PXR40 Microcontroller Reference Manual Rev 1...
Page 1167: ...Decimation Filter Freescale Semiconductor 28 53 PXR40 Microcontroller Reference Manual Rev 1...
Page 1168: ...Decimation Filter 28 54 Freescale Semiconductor PXR40 Microcontroller Reference Manual Rev 1...