DRIVE CONFIGURATION
Default Settings Table - PROT Menu
56
Default Settings Table - PROT Menu
CODE
Display
Basic
Supply Fan
Exhaust
Fan
Cooling
Tower
Centrifugal
Pump
Submersible
Pump
Vacuum
Pump
Constant
Torque
FE
MagForce PM Motor
PROT-00 Decel Method
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
PROT-01 Preheat Level
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
PROT-02 Preheat Duty
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
PROT-03 LV Level
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
PROT-04 OV Stall Level
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
PROT-05 OV Stall Prevent
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
PROT-06 SW Brake V Lvl
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
PROT-07 OCA Level
105%
105%
105%
105%
105%
105%
120%
150%
105%
105%
PROT-08 OCN Level
105%
105%
105%
105%
105%
105%
120%
150%
105%
105%
PROT-09 Auto Timer
Counter
10800
10800
10800
10800
10800
10800
10800
10800
10800
10800
PROT-10 Auto Restarts
3
3
3
3
3
3
3
3
3
3
PROT-11 Auto Retry Delay
120 Sec
120 Sec
120 Sec
120 Sec
120 Sec
120 Sec
120 Sec
120 Sec
120 Sec
120 Sec
PROT-12 OL-2 Type
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
PROT-13 OL-2 Level
120%
120%
120%
120%
120%
120%
120%
120%
120%
120%
PROT-14 OL-2 Delay
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
PROT-15 OCA/OCN ACC/
DEC
ACC/DEC-1 ACC/DEC-1 ACC/DEC-1 ACC/DEC-1 ACC/DEC-1 ACC/DEC-1 ACC/DEC-1 ACC/DEC-1 ACC/DEC-1 ACC/DEC-1
PROT-16 ETH Type
Self-Cooled Self-Cooled Self-Cooled Self-Cooled Self-Cooled Self-Cooled Self-Cooled Self-Cooled Self-Cooled Self-Cooled
PROT-17 ETH Delay
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
PROT-18 OH Warning
105 °C
105 °C
105 °C
105 °C
105 °C
105 °C
105 °C
105 °C
105 °C
105 °C
PROT-19 PTC/PTC100
Select
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
PROT-20 PTC Level
50%
50%
50%
50%
50%
50%
50%
50%
50%
50%
PROT-21 OPO Trip
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
Trip Coast
Stop
PROT-22 OPO Delay
0.5 Sec
0.5 Sec
0.5 Sec
0.5 Sec
0.5 Sec
0.5 Sec
0.5 Sec
0.5 Sec
0.5 Sec
0.5 Sec
PROT-23 OPO Current
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
PROT-24 OPO Decel
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
0 Sec
PROT-25 LvX Auto Reset
Enable
Enable
Enable
Enable
Enable
Enable
Enable
Enable
Enable
Enable
PROT-26 IPO Check Time
0.2 Sec
0.2 Sec
0.2 Sec
0.2 Sec
0.2 Sec
0.2 Sec
0.2 Sec
0.2 Sec
0.2 Sec
0.2 Sec
PROT-27 IPO Ripple
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
By VFD
Rating
PROT-28 IPO Trip
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
Alarm and
Decel
PROT-29 Derating Type
Carrier by
I_T
Carrier by
I_T
Carrier by
I_T
Carrier by
I_T
Carrier by
I_T
Carrier by I_T Carrier by
I_T
Carrier by
I_T
Carrier by
I_T
Carrier by
I_T
PROT-30 PT100 Level 1
60 °C
60 °C
60 °C
60 °C
60 °C
60 °C
60 °C
60 °C
60 °C
60 °C
PROT-31 PT100 Level 2
100 °C
100 °C
100 °C
100 °C
100 °C
100 °C
100 °C
100 °C
100 °C
100 °C
PROT-32 PT100 L- 1 Freq
0.5 Hz
0.5 Hz
0.5 Hz
0.5 Hz
0.5 Hz
0.5 Hz
0.5 Hz
0.5 Hz
0.5 Hz
0.5 Hz
PROT-33 PT100 L- 1 Delay
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
60 Sec
PROT-34 Gnd Fault Level
60%
60%
60%
60%
60%
60%
60%
60%
60%
60%
PROT-35 Gnd Fault Delay
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
0.1 Sec
PROT-36 STO Alarm Type
STO
Latching
STO
Latching
STO
Latching
STO
Latching
STO
Latching STO Latching
STO
Latching
STO
Latching
STO
Latching
STO
Latching
PROT-37 IPF S-Search
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
PROT-38 Max IPF Time
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
2 Sec
PROT-39 SS Current Lmt
100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
PROT-40 SS After Fault
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
PROT-42 SS Normal Start
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
Disable
PROT-43 Spd Search Gain
40%
40%
40%
40%
40%
40%
40%
40%
40%
40%
Summary of Contents for CERUS X-DRIVE CXD-003A-4V
Page 2: ......
Page 3: ...CERUS X DRIVE INSTALLATION AND OPERATION MANUAL Firmware Version 1 2 Franklin Electric Co Inc ...
Page 96: ...OPERATION Protection Features 96 ...
Page 112: ...ADVANCED APPLICATION OPTIONS Multi Drive Configurations 112 ...
Page 124: ...COMMUNICATIONS BACnet Communication 124 ...
Page 128: ...ACCESSORIES Optional Extension Cards 128 Frame D Frame E Frame F ...
Page 129: ...ACCESSORIES Optional Extension Cards 129 Frame G Frame H ...
Page 132: ...ACCESSORIES Optional Extension Cards 132 ...
Page 234: ...PARAMETER REFERENCE TABLES Parameter Descriptions Motor Menu 234 ...
Page 250: ...GLOSSARY 250 ...