SPECIFICATIONS
Maximum Frequency Output
244
Altitude Derating
Maximum Frequency Output
Induction Motor Max Frequency
Max Frequency By Model
*The carrier frequency should be set at least to 4k.
Altitude
Current
0-1000 m
Operate drive at rated current
1000-2000 m For every 100 m increase: Either 1) decrease rated current by 1%, or 2)
lower the temperature by 0.5 °C
2000 m
Maximum temperature allowable; do not exceed
100
90
95
85
% Rat
ed Output Curr
en
t
Altitude above sea level (M/Ft)
0
500/1640
1000/3281
1500/4921
2000/6562
2500/8202
80
Minimum Carrier Frequency Requirement
Maximum Operation Frequency
2k
200 Hz
3k
300 Hz
4k
400 Hz
5k
500 Hz
6k
599 Hz
VFD models
Maximum Operation Frequency
230V; 55kw +
200 Hz*
460V; 90kw +
300 Hz*
575V & 690 V
599 Hz