MAINTENANCE
Fan Replacement
195
Frame B and C Capacitor Fan
1.
Disconnect fan power connector.
2. Lift the fan out using a flathead screwdriver.
Frame C Heat Sink Fan
Some Frame C models use one fan and some use two.
1.
Before removing fans, remove the cover using a flathead screwdriver.
2. Disconnect fan power connectors.
3. Remove screws and remove fans. When replacing screws, tighten to a torque of 8.67 to 10.4 in-lbs
(0.98 to 1.18 Nm).
4. When installing new fans, make sure label faces the inside of the drive.
1
2
1
2
3