MAINTENANCE
Troubleshooting
146
LvS
(14)
Lv at Stop
DC bus low voltage at stop
Action and Reset
Action level
DC bus voltage is lower than
LV Level [PROT-03]
at constant speed
Action time
Immediately
Related parameters
LV Level [PROT-03]
Reset method
Manually or Automatically if in Auto mode and Auto Restart is enabled and depending on voltage recovery level
Reset condition
Voltage re500 ms
Recorded
Yes
Possible Causes
Corrective Action
• Incorrect drive model
• Power voltage change
• Hardware failure
• Check if the input voltage is normal
• Check for possible sudden load
• Adjust setting of
[PROT-03]
• Check DC reactor connection
• Cycle the power. If error still exists, please call Technical Support.
• If powered by a generator, increase the throttle.
• If powered by a generator, replace generator with large one
Fault Display
Description
MVWS
(183)
M-VFD Wrong Set
Wrong settings of Multi-VFD. Settings of follower (this drive) is different from the master.
Action and Reset
Action level
[ADV-35]
,
[ADV-36]
,
[SET-07]
, and
[SET-17]
different than master drive. To identify master drive, set
[SET-58]
to
23_Commu
Role
. On screen, 0 = No Role, 1 = Master, and 2 = Follower.
Action time
Immediately
Related parameters
[ADV-35]
;
[ADV-36]
;
[SET-07]
;
[SET-17]
Reset method
Automatically
Reset condition
Immediately
Recorded
Yes
Possible Causes
Corrective Action
• Wrong parameter values for
[ADV-35]
,
[ADV-36]
,
[SET-07]
, and
[SET-17]
• Multiple masters on network
• Verify settings match master drive. To identify master drive, set
[SET-58]
to
23_Commu Role
. On screen,
0=No Role, 1=Master, and 2=Follower.
• If network has multiple masters, make sure each drive on network has unique
Mulit-VFD [ADV-37]
and
that value is equal or less than
Multi-VFD Set [ADV-35]
.
• If network has multiple masters, check communication wiring between drives and replace wiring as
needed.
Fault Display
Description
Summary of Contents for CERUS X-DRIVE CXD-003A-4V
Page 2: ......
Page 3: ...CERUS X DRIVE INSTALLATION AND OPERATION MANUAL Firmware Version 1 2 Franklin Electric Co Inc ...
Page 96: ...OPERATION Protection Features 96 ...
Page 112: ...ADVANCED APPLICATION OPTIONS Multi Drive Configurations 112 ...
Page 124: ...COMMUNICATIONS BACnet Communication 124 ...
Page 128: ...ACCESSORIES Optional Extension Cards 128 Frame D Frame E Frame F ...
Page 129: ...ACCESSORIES Optional Extension Cards 129 Frame G Frame H ...
Page 132: ...ACCESSORIES Optional Extension Cards 132 ...
Page 234: ...PARAMETER REFERENCE TABLES Parameter Descriptions Motor Menu 234 ...
Page 250: ...GLOSSARY 250 ...