506
EPICenter Software Installation and User Guide
EPICenter Database Views
sysContact
string
The sysContact of the device.
read_write_community
string
The read/write SNMP community string.
read_only_community
string
The read-only SNMP community string.
cli_login
string
The CLI/Telnet login name of the device.
cli_password
string
The CLI/Telnet password for the above login.
status
string
The status of the device: “operational”, “marginal”, or “not responding”.
boot_time
string
The boot time of the device in GMT, e.g. “2000-11-13 21:05:28”.
hardware_id
string
The vendor specific hardware id of the device (not all device have a
hardware id).
reserved
string
Reserved field, only used by a Cisco device to store Cisco specific
information.
ip_forwarding
string
“true” if the device is a router, “false” otherwise.
current_software
string
The software version of the device.
The following columns are Extreme specific:
primary_image
string
The primary software image version on the device, e.g. “4.1.9 (2)”.
secondary_image
string
The secondary software image version on the device, e.g. “6.1.5b20”.
boot_rom
string
The version of the device’s boot rom, e.g. “7.2”.
image_after_reboot
string
The image to use after a switch reboot: “primary”, “secondary”, “neither”,
or “unknown”.
board_number
string
The hardware board number.
other_numbers
string
Other hardware board numbers.
serial_numbers
string
The serial number of the device.
fan_status_string
string
The status of all fans on the device, e.g. “fan 1 OK; fan 2 OK; fan 3
OK”.
selected_configuration
string
The currently selected configuration on the device: “primary” or
“secondary”.
power_status_string
string
The status of the primary power supply of the device: “fan/temperature
alarm”, “not present”, “OK”, “failed”, or “unknown”.
rps_status
string
The status of the redundant power supply of the device:
“fan/temperature alarm”, “not present”, “OK”, “failed”, or “unknown”.
voltage
string
The voltage of the power supplied to the device: “110 AC”, “220 AC”, “48
DC”, or “unknown”.
temperature
integer
The current operating temperature of the device in centigrade, e.g. 48.
default_gateway
string
The default gateway of the device, e.g. “10.205.0.1”.
Column Name
Column
Type
Description
Summary of Contents for EPICenter 4.1
Page 20: ...20 EPICenter Software Installation and User Guide Preface ...
Page 46: ...46 EPICenter Software Installation and User Guide EPICenter and Policy Manager Overview ...
Page 190: ...190 EPICenter Software Installation and User Guide Configuration Manager ...
Page 204: ...204 EPICenter Software Installation and User Guide Using the Interactive Telnet Application ...
Page 242: ...242 EPICenter Software Installation and User Guide Using the IP MAC Address Finder ...
Page 266: ...266 EPICenter Software Installation and User Guide Using ExtremeView ...
Page 284: ...284 EPICenter Software Installation and User Guide Real Time Statistics ...
Page 436: ...436 EPICenter Software Installation and User Guide Using the Policy Manager ...
Page 454: ...454 EPICenter Software Installation and User Guide The ACL Viewer ...
Page 468: ...468 EPICenter Software Installation and User Guide Troubleshooting ...
Page 504: ...504 EPICenter Software Installation and User Guide EPICenter External Access Protocol ...