Aquastorm 200
7
7
Start-Up and Operation 3-7
Final Rinse Control
Press the Final Rinse Control to activate the final
rinse solenoid.
The green final rinse indicator illuminates
to indicate the final rinse is activated.
Press the final rinse control again to deactivate
final rinse.
The indicator no longer illuminates
indicating the final rinse solenoid is
deactivated.
When the Aquastorm 200
™
is configured with
the optional Resys CLS (Closed Loop System)
Treatment Interface System, the Final Rinse
control also activates the treatment interface
system's pump. As long as the Final Rinse remains
on, so does the treatment system pump.
When the final rinse is turned off, the treatment
interface system pump turns off.
Press the Wash/Hurricane Pump On/Off
Control again to deactivate the recirculating
pump.
Wash JIC Pump On/Off
Control
The Wash JIC Pump On/ Off control is not
applicable on the Aquastorm 200
™
series aqueous
cleaning system. This control is reserved for use
with the 300 series cleaner.
Sump Pump
High Level Indicator
If a High Level condition becomes present in the
sump pump reservoir, the red sump pump
indicator illuminates, the audible alarm sounds,
the red Alarm Acknowledge indicator illuminates,
and all drain solenoids are disabled.
Press the Alarm Acknowledge Control to silence
the audible alarm.
Wash/Hurricane Pump
On/Off Control
Press the Wash/Hurricane Pump On/Off
Control to activate the wash/ Hurricane pump.
The Wash/Hurricane pump green on
indicator illuminates when the Wash/
Hurricane Pump On/Off control is
pressed.
The Wash/ Hurricane Pump On/ Off
Control also activates the prewash spray
manifolds.