Aquastorm 200
Maintenance 4-39
Spray Nozzle
Cleaning Procedure
The spray nozzles in the Prewash, Wash,
Optional Chemical Isolation, Rinse and Final
Rinse sections periodically become clogged with
debris such as solder balls, polypropylene or cpvc
particles, silicone and other foreign debris.
1
Use a small diameter piece of wire and
insert it through the spray end of the
nozzle to force out any debris which may
be clogging or altering the spraying power
of the nozzle.
2
Use the wire and lightly scrape the inside
edges of the nozzle from the opposite end
to loosen any additional debris.
3
Rinse thoroughly in water. Use the facility
air supply to blow out the nozzle.
4
Reinspect the spray nozzle to ensure it is
clean.
5
If the spray nozzle can not be cleaned,
replace it with a new one.
6
Proceed to the spray manifold
reassembly procedure.
Spray Nozzle
Top View
Side View
Insert a small diameter
piece of wire into the
spray nozzle orifice to
dislodge any material
clogging the nozzle
Then use the wire to scrape
the inside of the nozzle
cavity from the opposite end