Aquastorm 200
4-52 Maintenance
Tool Kit Required for the Turbine Blower Belt
Replacement Procedure
5
/
16
" Nut Driver
13 mm Open End Wrench
9
/
16
" Open End Wrench
3
/
4
" Drive Socket
3
/
8
" Drive Ratchet with
3
/
8
" Drive 2.0" Extension
3
/
16
" Allen Wrench
Main Power Disconnect
3.6
TURBINE BLOWER BELT
REPLACEMENT
NOTE
It is recommended to replace
turbine blower belts every six (6)
months or every 1000 hours of
operation, whichever comes first.
1
Press the
Main Power Off Control via
the membrane keypad.
2
Turn off the main power disconnect for
Aquastorm 200
™
system.
3
Locate the blower sections at the rear exit
end of the Aquastorm 200
™
cabinet.
4
Remove the rear blower section access
panels.
Rear View of Aquastorm 200 with Rear Access Panels Removed
Blower Sections