Aquastorm 200
4-58 Maintenance
12
Using a
3
/
16
Allen wrench, loosen the two
(2)
1
/
4
-20 x
3
/
4
" socket head cap screws
securing the turbine blower belt guard,
then remove the guard.
Turbine Blower
Blower Motor
Blower Belt Cover
3/16" Allen Wrench
1/4-20 x 3/4" Socket Head Screws
NOTE
Belt configurations on turbine blowers will vary, depending on horsepower and Hz rating,
Some turbine blowers may be configured with a three (3) strand belt and some may be
configured with a five (5) strand belt. Refer to the Blower Configuration Chart on this
page for specifications which apply to your system configuration.
Blower Belt Tension Chart
HP
Hz
Belt Size Belt Tension (krikit™
7.5
60
3 Strand
110 - 120 lbs (50 - 54
7.5
50
5 Strand
130 - 140 lbs (59 - 64
10
60
3 Strand
110 - 120 lbs (50 - 54
10
50
5 Strand
130 - 140 lbs (59 - 64
15
60
5 Strand
140 - 150 lbs (64 - 68
15
50
5 Strand
140 - 150 lbs (64 - 68