Maintenance 4-25
Aquastorm 200
There are two (2) ways to hold the belt tension
gauge:
Î
Position the thumb and forefinger as
illustrated in the photograph labeled
Gauge Figure 1.
Î
Position the thumb in the thumb pad
holder as illustrated in the photograph
labeled Gauge Figure 2.
Press down slowly on the belt tension gauge pad
to get an accurate reading.
When you feel and hear a click from the tension
gauge, immediately release pressure and carefully
remove the gauge so as not to move the indicator
arm.
Refer to the photograph labeled Gauge Figure 3
which illustrates how to read the Krikit
TM
II
Gauge accurately.
It is recommended to take more than one (1)
belt tension reading to assure repeatable
measurements.
If the readings taken are not within tolerance,
refer to the Corrective Maintenance section in
this manual and perform the Turbine Blower Belt
Tensioning Procedure.
8
Visually inspect the blower belt for wear.
If the belt appears to be excessively worn,
refer to the Corrective Maintenance
section in this manual for the Turbine
Blower Pulley Alignment Procedure or
Turbine Blower Belt Replacement
procedure.
9
Reinstall the belt guard with the two (2)
1
/
4
-20 x
3
/
4
in. socket head cap screws
using a
3
/
16
in. Allen wrench to tighten
them securely.
10
Reinstall the rear access panels.
Gauge Figure 1
Finger Strap
Forefinger on this side
Thumb on this side
Position Thumb and Forefinger on either side of Finger Strap
so that the Finger Strap is held between the Thumb and Forefinger
Gauge Figure 2
Finger Strap
Position Thumb on Pad inside the Finger Strap
Pad
Gauge Figure 3
Indicator Arm
Position the Krikit gauge sideways as depicted in the photo above to read
the exact point on the scale where the indicator arm intersects the scale.
Take caution not to move the indicator.
Scale
Summary of Contents for Aquastrom 200
Page 48: ......