4-34 Maintenance
Aquastorm 200
MIN Trim Pot
MAX Trim Pot
IR COMP Trim Pot
CUR LIM Trim Pot
GAIN Trim Pot
P4 Jumper
Pins 1, 2, & 3
DART Conveyor Speed Control Board
SECTION 2
CALIBRATION
2.1
DART CONVEYOR MOTOR
SPEED CONTROL CALIBRATION
1
Turn the MIN, MAX, IR COMP, CUR
LIM, and GAIN trim potentiometers,
located on the speed control board, to the
full counterclockwise position.
NOTE
Each trim pot will click but not
stop at the full counterclockwise
setting.
2
Set P4 jumper between pins 2 and 3.
3
Set the control voltage of pins 1 and 3 on
P3 to "0" vdc.
4
Turn MIN control clockwise until the
conveyor starts to move, then slightly
counterclockwise until the conveyor just
stops.
5
Set the control voltage of pins 1 and 3 on
P3 to "5" vdc.
6
Turnt the GAIN potentiometer clockwise
until no further increase in output voltage
occurs; back off one turn, then set the
MAX potentiometer for 90 vdc output
voltage.