Aquastorm 200
2-4 System Preparation
1.4
ADJUSTING TANK
TEMPERATURES
Refer to the following procedures to set the Wash,
Rinse, and Optional Chemical Isolation tank
temperature set points.
MODULE SETP ACTUAL
* WASH 151F 141
* CHEM_ISO 151F 150
* RINSE 99F 86
DRYER_1 F 81
DRYER_2 F 85
CONVEYOR 3.0FPM 0.0
AQUASTORM 200
Temperature Set Point
Adjustments
A flashing square curser is visible
on the LCD screen, next to the
component's set point value when
it is ready for adjustment.
1
With system power ON,
press the Up or Down
Arrow Key on the LCD
interface keypad to move
the square curser to the
section on the LCD
requiring adjustment.
2
Once the curser is in front
of the required section
enter the set point using
the number keys on the
LCD interface keypad.
NOTE
Enter set point
values between 60 -
71
o
C (140 - 160
o
F), depending on
your process
application.
3
When the correct set point temperature is
displayed on the LCD, press the Enter key
on the LDC interface keypad to accecpt
the new set point value.
Perform steps 1 - 3 in this procedure for the
Wash, optional Chemical Isolation and Rinse
section tanks as well as for the Radiant Heater
option.
NOTE
The set point value may also be
adjusted by using the up or down
arrow keys on the membrane
keypad.