Aquastorm 200
™
Maintenance 4-77
nozzle while cleaning it. Altering the
Hurricane Jet™ orifice will adversely
affect the sheeting action normally
produced by Hurricane Jet™.
7
Slide the feeler gauge back and forth
inside the orifice to dislodge any debris
which may be clogging the Hurricane
Jet
™
nozzle orifice.
8
Use a compressed air supply with clean,
dry air to blow the air through the end,
and through the orifice of the Hurricane
Jet
™
nozzle to remove the debris.
9
Repeat the cleaning steps as necessary to
remove any additional debris.
10
Flush the insert tube with water and use a
compressed air supply with clean, dry air
to blow the air through the end, and
through the holes to remove debris from
the tube.
11
Reassemble the Hurricane Jet
™
nozzle in
the reverse manner of disassembly.
While the Hurricane Jet™ Nozzle is disassembled Insert a
.020 feeler Gauge into the Nozzle's Orifice, then Slide the
Feeler Gauge Back and Forth to Clear the Orifice.
Hurricane Jet™ Nozzle
.020 Feeler Gauge