Aquastorm 200
Overview 1-7
An optional Hurricane Jet
TM
performance kit may
be configured which includes a 10 HP pump in
lieu of the standard 5 HP pump. The Hurricane
Jet
TM
manifold is configured between the
standard four (4) upper spray manifolds.
The water level in the wash tank is monitored by
means of liquid level float switches. If the tank
fluid level falls below the low level float switch,
the tank heaters shut off and trip the tank level
alarm indicator on the front control panel along
with an audible alarm.
Tank filling is automatic via the fill solenoid,
activated by the low and/or operating liquid level
float switch(es) in the wash tank. When the
system is initially activated and the tank is empty,
the fill solenoid activates to fill the system tanks.
During normal operation, if the water level falls
below normal operating level, the fill solenoid
activates to fill the tank.
Heated Recirculating Wash
Hurricane Section
The Recirculating Wash section is 122 cm (48
inches) long consisting of four (4) upper spray
manifolds and four (4) lower spray manifolds,
powered by a 5 HP pump (standard
configuration). A 303 liter (80 gal.) tank is
standard with two (2) 16 kw immersion heaters.
Temperatures are displayed via the LCD (Liquid
Crystal Display). The computer continually
monitors and corrects the temperature in the
wash tank by means of a thermocouple device. If
the temperature exceeds 82
o
C (180
o
F), the
tank's high temperature alarm indicator
illuminates, the audible alarm sounds and the
tank heaters shut off.