Aquastorm 200
Maintenance 4-53
L
L
oosen Hose Clamp Here
oosen Hose Clamp Here
then lift R
then lift R
ubber Union from
ubber Union from
Blower Housing
Blower Housing
Belt Guard
Belt Guard
5
Access the blower assembly at the rear of
the machine. Use a
5
/
16
" nut driver to
loosen the hose clamp on the rubber union
at the blower housing.
6
Lift the rubber union from the blower
housing to free the blower assembly for
movement.
7
Allow the blower manifold assembly to
hang freely from the rear bulkhead.
8
For systems configured with the Optional
Slide-Out Access for the blowers, perform
step 9, then proceed to step 11.
For systems configured without the
M8 x 50 Hex Head Bolt
M8 Nut
M8 Flat & Lock Washer
M8 Flat Washer
3/4" Spacer
Optional Slide-Out Access for the blowers
perform steps 10A and 10B, then proceed
to step 11.
9
Locate the M8 hardware securing the
Slide-Out blower trays; using a 13 mm
open end wrench and a 13 mm socket with
ratchet, remove the M8 x 50 hex head
bolt, M8 nut, M8 lock and flat washers,
and 3/4" spacers from either side of the
tray closest to the rear of the machine.
10A
Use a
7
/
16
" open end wrench to loosen and
remove the three (3) front most blower
base plate mounting bolts (M8 x 35) of the
four (4) that are securig it.
10B
Pivot the blower to the right as far as
possible to allow access to the blower belt
guard.
11
Locate the belt guard on the turbine
blower.