Maintenance 4-31
Aquastorm 200
Rear Plumbing Inspection
1
Inspect all rear plumbing at each "Kwik
Clamp" connection for leaks.
2
If a leak is present, first try tightening the
Kwik Clamp to seat the Teflon
®
O-ring
between the two (2) plumbing
connections.
Test the connection for leaks by purging
the respective pump, or activating the
water source for that specific leak's
location.
If the leak is remains present, perform
step 3 of Rear Plumbing Inspection.
3
If the Kwik Clamp connection continues
to leak, replace the Teflon
®
O -ring
between the two (2) plumbing
connections.
If the leak is located in the lower stainless
steel plumbing area, it will be necessary to
drain the respective tank.
Once the tank is drained, or if the leak is
in the upper stainless steel plumbing area,
simply loosen and remove the Kwik Clamp
connection.
Remove the Teflon
®
O-ring and replace it
with a new one.
NOTE
Once a Teflon
®
O-ring has been
used and removed, it cannot be
re-used.
Refer to the chart below for a list of the different
size Teflon
®
O-rings and the corresponding
Electrovert replacement part numbers.
Teflon
®
O-Ring Gasket Chart
Plumbing Size
3
/
4
Inch
1
1
/
2
Inch
2.0 Inch
Part
Number
2-8999-240-00-0
2-8999-242-00-0
2-8999-486-00-0
"Kwik Clamp"
Connection
Ventilation
1
Inspect the external venting system.
2
Verify that all joints are tight and no
condensate is escaping through the joints.
3
Inspect any slide gate dampers on the
stack tubes for proper positioning.
Optional Detergent
Injection System
1
Inspect the suction line to the detergent
injection nozzle, as certain chemicals used
may damage the material.
2
Replace damaged suction lines.
Detergent
Suction Line
Summary of Contents for Aquastrom 200
Page 48: ......
Page 142: ...Aquastorm 200 Maintenance 4 49 ...