4-20 Maintenance
Aquastorm 200
32
Inspect the pump inlet recirculation filters
in the system tanks. If the filters still
appear to be clogged and/or
contaminated with scale residue,
replacement is required.
Immersion Heaters
Drain
Screen
Pump Inlet Filter
Reference Electrovert p/n
2-8999-230-00-0
for the replacement stainless steel recirculation
filter.
Refer to the corrective maintenance
section of this manual for the
recirculation filter replacement
Procedure.
33
Inspect the immersion heaters in the
wash, rinse, and optional chemical
isolation tanks for excessive scale
deposits. If excessive scale is still present,
replacement is required.
Reference the following Electrovert part
numbers for the immersion heater that
applies to your system's voltage:
230 V
p/n
2-5002-428-00-0
380 V
p/n
2-5002-428-00-0
460 V
p/n
2-5002-429-00-0
Refer to the corrective maintenance
section of this manual for the
immersion heater replacement
procedure.
Summary of Contents for Aquastrom 200
Page 48: ......
Page 142: ...Aquastorm 200 Maintenance 4 49 ...