Start-Up and Operation 3-5
The alarm sounds on the original occurrence of
an alarm until the Alarm Acknowledge control is
pressed. This applies to the following LED
indicators;
• Wash Low Level
• Wash High Level
• Wash High Temp
• Chemical Isolation Low Level
• Chemical Isolation High Level
• Chemical Isolation High Temp
• Rinse Low Level
• Rinse High Level
• Rinse High Temp
• Sump Pump High Level
• Radiant Heater High Temp
• Optional Sump Pump High Level
When an alarm occurs:
• The alarm message is displayed on the LCD
• Audible alarm sounds
• Alarm Acknowledge Control's red LED flashes
• System goes into Power Off state, if it is an
alarm configured for SHUTDOWN
When the Alarm Acknowledge Control is pressed
during an alarm, the following will occur:
• Alarm message is cleared from the LCD and
the Main Menu screen is displayed
• Alarm silences
• If the alarm condition still exists, the red LED
on the Alarm Acknowledge Control remains
flashing
If the alarm condition clears or is cleared, the
LED stops flashing
When the system is restarted after clearing a
SHUTDOWN condition, the system Power Off
indicator remains illuminated. Pressing the
Power On Control brings the system back into
operation.
If the Power On Control is pressed and the alarm
condition is not cleared, the alarm condition
reoccurs with the four (4) items listed under
"When an alarm occurs".
The illustrations below represent typical LED
indication for Temperature and Level indicators.
High Temperature Deviation
Low Temperature Deviation
Low Temperature
Set Point/ Operating Temperature
High Level
Approaching Low Level
Operating Level
Low Level
Temperature Indicator
High Temperature
Level Indicator