4-18 Maintenance
Aquastorm 200
NOTE
The rinse tank and optional
chemical isolation tank capacities
are less than the wash tank
capacity. Refer to the descaler
manufacturers' specifications for
correct mixing ratio for each tank
capacity.
15
Add descaler to the tanks with the correct
mixing ratio as specified by the descaler
manufacturer.
16
Press the Wash/ Hurricane, Rinse/
Hurricane, and optional Chemical
Isolation pump On/Off Controls to
enable the recirculation pumps.
If tap water is being used in the final
rinse section, also rinse this section
thoroughly with clean water. Ensure all
surfaces and interior components are
rinsed.
10
Once all sections are thoroughly rinsed,
close each of the tank drain valves.
11
Reinstall the tank castch screens.
12
Reinstall the tank lids.
13
Press the Power On Control to enable
power to the system.
The wash, rinse, and optional chemical
isolation tank fill solenoids activate to fill
the tanks.
Once the tanks are full, the tank heaters
activate.
14
Now adjust the temperature settings for
each of the tanks via the LCD interface
keypad to bring the temperature of the
water up to the descaler manufacturers'
specifications outlined for the descaler
being used.
Temperatures are not to exceed safety
limits of 74
o
C (165
o
F).
MODULE SETP ACTUAL
WASH 151F 141
CHEM_ISO 151F 150
RINSE 99F 86
DRYER_1 F 81
DRYER_2 F 85
CONVEYOR 3.0FPM 0.0
AQUASTORM 200
Main Power On
Main Power Off
Auto Sequential
Mode
Alarm Acknowledge
Photocell On/ Off
Final Rinse On/ Off
Sump Pump On/ Off -
Hi Level Indicator
Conveyor On
Conveyor Off
Conveyor
Forward
Conveyor
Reverse
Decrease
Speed
Increase
Speed
Decrease
Temperature
IR Dryer
Temp Level
Indicator
Blower #4
On/ Off
Blower #3
On/ Off
Blower #1
On/ Off
Blower #2
On/ Off
IR Dryer
On/ Off
Increase
Temperature
Rinse Tank
Temp Level
Indicator
Decrease
Temperature
Rinse Tank
Level Indicator
Rinse Tank
Drain
Rinse JIC
Pump On/ Off
Configurable
Function Key
Configurable
Function Key
Rinse/ Hurricane
Pump On/ Off
Rinse Tank
Fill
Increase
Temperature
Chemical Isolation
Tank Temp
Level Indicator
Decrease
Temperature
Chemical
Isolation
Tank Level
Indicator
Chemical
Isolation
Tank Drain
Chemical
Isolation
Blower On/ Off
Chemical
Isolation
Pump On/ Off
Chemical Isolation
Tank Fill
Increase
Temperature
Decrease
Temperature
Wash Tank
Temp Level
Indicator
WashTank
Level
Indicator
Wash
Tank Drain
Wash JIC
Pump On/ Off
Wash/ Hurricane
Pump On/ Off
Wash Tank
Fill
Increase
Temperature