Aquastorm 200
4-56 Maintenance
3.7
TURBINE BLOWER BELT
TENSIONING PROCEDURE
Tool Kit Required for the Turbine Blower Belt
Replacement Procedure
5
/
16
" Nut Driver
13 mm Open End Wrench
9
/
16
" Open End Wrench
3
/
4
" Drive Socket
3
/
8
" Drive Ratchet with
3
/
8
" Drive 2.0" Extension
3
/
16
" Allen Wrench
Krikit II Belt Tension Gauge
Flashlight
1
Press the
Main Power Off Control via
the membrane keypad.
2
Turn off the main power disconnect for
Aquastorm 200
™
system.
3
Locate the blower sections at the rear exit
end of the Aquastorm 200
™
cabinet.
4
Remove the rear blower section access
panels.
Rear View of Aquastorm 200 with Rear Access Panels Removed
Blower Sections
Main Power Disconnect