Aquastorm 200
Maintenance 4-37
SECTION 3
CORRECTIVE MAINTENANCE
3.1
SPRAY MANIFOLD MAINTENANCE
1
Observe the spray patterns of all upper
and lower spray nozzles.
2
Inspect for any which appear to be
altered or obstructed.
Inspect Spray Patterns
3
Tag or label the nozzle(s) which appear to
be clogged.
4
Press the following controls to turn off the
recirculation pumps.
Wash/Hurricane Pump
On/Off Control
Rinse/Hurricane Pump
On/Off Control
Optional Chemical Isolation Pump
On/ Off Control
•
The green indicators are off to indicate
the pumps are off.
NOTE
It may be necessary to decrease spray nozzle pressures to determine whether spray
nozzles are clogged. This can be done on the lower spray manifolds by turning the ball
valve in the system rear cabinet which corresponds to the spray manifold for that section,
in a counterclockwise direction until minimal spray nozzle flow is observed. With the
pressure decreased, a clogged nozzle in the spray manifolds will have a noticeably
diminished flow, compared to those which are not clogged.
Summary of Contents for Aquastrom 200
Page 48: ......
Page 142: ...Aquastorm 200 Maintenance 4 49 ...