Aquastorm 200
Maintenance 4-65
3.9
TURBINE BLOWER AIR
FILTER REPLACEMENT
1
Press the Main Power Off Control via the
custom interface keypad to deactivate
system power.
2
Turn off the system power via the system
disconnect at the exit end of the
Aquastorm 200
™
cabinet.
3
Locate the blower sections at the rear exit
end of the Aquastorm 200
™
.
4
Remove the front access panels to the
blower enclosures.
5
Remove the wing nut from the top of the
filter houseing, then remove the top
housing to access and remove the blower
filter.
6
Remove the air filter from the filter
housing.
7
Place the new air filter, reference
Electrovert p/n
2-8999-523-00-0
, in the
air filter housing and reassemble in the
reverse manner of disassembly.
Blower Air Filter p/n 2-8999-523-00-0
Wing Nut
Top of Filter Housing
Blower Filter
Summary of Contents for Aquastrom 200
Page 48: ......