Use this parameter to set the threshold value for computing the alarm/fault high notification threshold. Threshold value range var-
ies based on alarm/fault mode selection. This limit is not used when value is zero.
10.557 (ID 3524) Current Alarm/Fault Delay
Location in the menu:
P2.13.3.4.9
(Multi-purpose Control Application)
Use this parameter to define how long time the actual value must be above the alarm/fault notification level to trigger the alarm/
fault. This level is not used when delay is zero.
10.558 (ID 3526) Voltage Mean Factor
Location in the menu:
P2.13.3.6.1
(Multi-purpose Control Application)
The several statistical data points (mean, minimum, maximum, and standard) from the baseline model can be combined into one
threshold value. Use this parameter to set the mean factor in the threshold value. If the threshold value is zero, the mean factor is
not used.
See the formula in
10.544 (ID 3511) Current Mean Factor
.
10.559 (ID 3527) Voltage Min Factor
Location in the menu:
P2.13.3.6.2
(Multi-purpose Control Application)
The several statistical data points (mean, minimum, maximum, and standard) from the baseline model can be combined into one
threshold value. Use this parameter to set the min factor in the threshold value. If the threshold value is zero, the min factor is not
used.
See the formula in
10.544 (ID 3511) Current Mean Factor
.
10.560 (ID 3528) Voltage Max Factor
Location in the menu:
P2.13.3.6.3
(Multi-purpose Control Application)
The several statistical data points (mean, minimum, maximum, and standard) from the baseline model can be combined into one
threshold value. Use this parameter to set the max factor in the threshold value. If the threshold value is zero, the max factor is not
used.
See the formula in
10.544 (ID 3511) Current Mean Factor
.
10.561 (ID 3529) Voltage Std Factor
Location in the menu:
P2.13.3.6.4
(Multi-purpose Control Application)
The several statistical data points (mean, minimum, maximum, and standard) from the baseline model can be combined into one
threshold value. Use this parameter to set the std factor in the threshold value. If the threshold value is zero, the std factor is not
used.
See the formula in
10.544 (ID 3511) Current Mean Factor
.
10.562 (ID 3530) Voltage Interpolation Type
Location in the menu:
P2.13.3.6.5
(Multi-purpose Control Application)
Use this parameter to select interpolation type for the notification threshold values across frequency points.
See figure in
10.548 (ID 3515) Current Interpolation Type
10.563 (ID 3531) Voltage Warning S1 Mode
Location in the menu:
P2.13.3.7.1
(Multi-purpose Control Application)
Use this parameter to select the warning S1 mode which is used for calculating warning S1 notification threshold.
Selection number
Selection name
Description
0
Absolute
Absolute value is considered as threshold
1
Offset
Calculates threshold as sum of the computed baseline data and the offset values
2
Factor
Calculates threshold as baseline data factor
10.564 (ID 3532) Voltage Warning S1 High
Location in the menu:
P2.13.3.7.2
(Multi-purpose Control Application)
AB296635287482en-000301 / DPD00903
298 | Danfoss A/S © 2023.02
Parameter Descriptions
VACON® NX All-in-One
Application Guide