Code
E061
Cause
• Video controller PCB (faulty)
• Laser unit (faulty)
• Scanner (faulty)
• Video controller PCB (faulty)
• Laser intensity (poor adjustment)
• Laser unit (faulty)
• Laser unit (faulty)
• Laser shutter (faulty)
• Photosensitive drum (faulty)
• Scanner (faulty)
• Video controller PCB (faulty)
• Laser intensity (adjustment faulty)
• Potential measurement unit
(faulty)
• HVDC (faulty)
• Laser unit (faulty)
• Video controller PCB (faulty)
• Laser intensity (adjustment fault)
Description
xx16
The difference between VD1 and VL1
measurements is 20 V or less and, in
addition, the measurement of VD1 is
200 V or more.
The difference between VD2 and VL2
measurements is 200 V or less and, in
addition, the VD2 measurement is 600
V or higher.
xx17
The VL1 measurement is 200 V or
higher and, in addition, the VL2 meas-
urement is 400 V or higher.
xx21
The computation value of Vdc is the
upper limit value (750 V) or higher.
xx22
The computation value of Vg is the
upper limit value (950 V) or higher.
xx23
The computation value of V00 is the
upper limit value (950 V) or higher.
xx24
The computation value of Vdc is the
lower limit value (200 V) or lower.
xx25
The computation value of V00 is the
lower limit value (325 V) or lower.
xx26
The computation value of Vg is the
lower limit value (250 V) or lower.
xx27
The computation value of VFF is the
lower limit value (700 V) or lower.
xx28
The computation value of VFF is the
lower limit value (0 V) or lower.
Summary of Contents for Vizcam 1000
Page 12: ......
Page 30: ......
Page 44: ......
Page 86: ......
Page 254: ......
Page 372: ......
Page 374: ......
Page 418: ......
Page 438: ......
Page 442: ......
Page 754: ......
Page 764: ......
Page 766: ......
Page 840: ...0501GR PRINTED IN JAPAN IMPRIME AU JAPON This publication is printed on 100 reprocessed paper...