COPYRIGHT © 2001 CANON INC. CLC1000/1000S/3100 REV.2 MAY 2001 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-93
4. MECHANICAL SYSTEM
4)
Remove the two mounting screws [4], and
remove the shutter cover [3].
Clean the shutter cover with lint-free paper.
Figure 4-907E
5)
Remove the spring [5], and remove the shutter
[6].
Clean the shutter with lint-free paper.
Figure 4-908E
6)
Clean the SALT sensor inside plastic sheet
[7], shutter contact member [8] with lint-free
paper moistened with alcohol.
Use dry lint-free paper for the SALT sensor
face [9].
Figure 4-909E
7)
Install all parts by reversing the steps used to
remove them.
8)
Check to make sure that the shutter moves
smoothly.
F. No. 2 Scoop-Up Sheet
1. Removing the No. 2 Scoop-Up
Sheet
1)
Remove the SALT sensor unit.
2)
Remove the two screws [1], and remove the
No. 2 scoop-up sheet [2].
[3]
[4]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[2]
[1]
[1]
Figure 4-901F